Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Jul-Aug;8(4):253-7.
doi: 10.1097/IMI.0000000000000007.

Two alternative sutureless strategies for aortic valve replacement: a two-center experience

Affiliations
Comparative Study

Two alternative sutureless strategies for aortic valve replacement: a two-center experience

Giovanni Concistrè et al. Innovations (Phila). 2013 Jul-Aug.

Abstract

Objective: Important comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses.

Methods: We compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S (P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy).

Results: Baseline patient characteristics were similar in both groups, except for mean ± SD body surface area (P group = 2.01 ± 2.9 m, E group = 1.83 ± 3.8 m; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group (P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group (P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm (P group) compared with 22.1 ± 2 mm (E group) (P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group (P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients (P group = 1, E group = 4), a moderate paravalvular leak was present (P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable (P = 0.017).

Conclusions: Aortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.