Miniaturization: the clue to clinical application of the artificial placenta
- PMID: 24147856
- DOI: 10.1111/aor.12146
Miniaturization: the clue to clinical application of the artificial placenta
Abstract
The artificial placenta as a fascinating treatment alternative for neonatal lung failure has been the subject of clinical research for over 50 years. Pumpless systems have been in use since 1986. However, inappropriate dimensioning of commercially available oxygenators has wasted some of the theoretical advantages of this concept. Disproportional shunt fractions can cause congestive heart failure. Blood priming of large oxygenators and circuits dilutes fetal hemoglobin (as the superior oxygen carrier), is potentially infectious, and causes inflammatory reactions. Flow demands of large extracorporeal circuits require cannula sizes that are not appropriate for use in preterm infants. NeonatOx, a tailored low-volume oxygenator for this purpose, has proven the feasibility of this principle before. We now report the advances in biological performance of a refined version of this specialized oxygenator.
Keywords: Artificial placenta; Extracorporeal life support; Interventional lung assist; Neonatal respiratory failure.
© 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.
Similar articles
-
Fifty years of work on the artificial placenta: milestones in the history of extracorporeal support of the premature newborn.Artif Organs. 2012 Jun;36(6):512-6. doi: 10.1111/j.1525-1594.2011.01404.x. Epub 2012 Feb 6. Artif Organs. 2012. PMID: 22309513 Review.
-
NeonatOx: a pumpless extracorporeal lung support for premature neonates.Artif Organs. 2011 Nov;35(11):997-1001. doi: 10.1111/j.1525-1594.2011.01324.x. Epub 2011 Oct 14. Artif Organs. 2011. PMID: 21995519
-
ECLS for preemies: the artificial placenta.Semin Perinatol. 2014 Mar;38(2):122-9. doi: 10.1053/j.semperi.2013.11.007. Semin Perinatol. 2014. PMID: 24580768
-
Artificial placenta--lung assist devices for term and preterm newborns with respiratory failure.Int J Artif Organs. 2013 Jun 25;36(6):377-91. doi: 10.5301/ijao.5000195. Epub 2013 May 6. Int J Artif Organs. 2013. PMID: 23645582 Review.
-
Novel modification of an artificial placenta: pumpless arteriovenous extracorporeal life support in a premature lamb model.Pediatr Res. 2012 Nov;72(5):490-4. doi: 10.1038/pr.2012.108. Epub 2012 Aug 10. Pediatr Res. 2012. PMID: 22885413
Cited by
-
An extra-uterine system to physiologically support the extreme premature lamb.Nat Commun. 2017 Apr 25;8:15112. doi: 10.1038/ncomms15112. Nat Commun. 2017. PMID: 28440792 Free PMC article.
-
Umbilical cannulation optimizes circuit flows in premature lambs supported by the EXTra-uterine Environment for Neonatal Development (EXTEND).J Physiol. 2018 May 1;596(9):1575-1585. doi: 10.1113/JP275367. Epub 2018 Mar 2. J Physiol. 2018. PMID: 29392729 Free PMC article.
-
Interprofessional Consensus Regarding Design Requirements for Liquid-Based Perinatal Life Support (PLS) Technology.Front Pediatr. 2022 Jan 19;9:793531. doi: 10.3389/fped.2021.793531. eCollection 2021. Front Pediatr. 2022. PMID: 35127593 Free PMC article.
-
Artificial Placenta and Artificial Womb Technologies for Lung and Kidney Failure: A Holistic Perspective.ASAIO J. 2025 Jul 1;71(7):519-527. doi: 10.1097/MAT.0000000000002443. Epub 2025 Apr 25. ASAIO J. 2025. PMID: 40279540 Free PMC article. Review.
-
Impact of the Addition of a Centrifugal Pump in a Preterm Miniature Pig Model of the Artificial Placenta.Front Physiol. 2022 Jul 22;13:925772. doi: 10.3389/fphys.2022.925772. eCollection 2022. Front Physiol. 2022. PMID: 35941934 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical