The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm
- PMID: 24150930
- DOI: 10.1177/0309364613506913
The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm
Abstract
Background and aim: DEKA Integrated Solutions Corp. (DEKA) was charged by the Defense Advanced Research Project Agency to design a prosthetic arm system that would be a dramatic improvement compared with the existing state of the art. The purpose of this article is to describe the two DEKA Arm prototypes (Gen 2 and Gen 3) used in the Veterans Affairs Study to optimize the DEKA Arm.
Technique: This article reports on the features and functionality of the Gen 2 and Gen 3 prototypes discussing weight, cosmesis, grips, powered movements Endpoint, prosthetic controls, prosthetist interface, power sources, user notifications, troubleshooting, and specialized socket features; pointing out changes made during the optimization efforts.
Discussion: The DEKA Arm is available in three configurations: radial configuration, humeral configuration, and shoulder configuration. All configurations have six preprogrammed grip patterns and four wrist movements. The humeral configuration has four powered elbow movements. The shoulder configuration uses Endpoint Control to perform simultaneous multi-joint movements. Three versions of foot controls were used as inputs. The Gen 3 incorporated major design changes, including a compound wrist that combined radial deviation with wrist flexion and ulnar deviation with wrist extension, an internal battery for the humeral configuration and shoulder configuration, and embedded wrist display.
Clinical relevance: The DEKA Arm is an advanced upper limb prosthesis, not yet available for commercial use. It has functionality that surpasses currently available technology. This manuscript describes the features and functionality of two prototypes of the DEKA Arm, the Gen 2 and the Gen 3.
Keywords: Amputation; assistive technology; prosthetics; upper limb.
© The International Society for Prosthetics and Orthotics 2013.
Similar articles
-
Do users want to receive a DEKA Arm and why? Overall findings from the Veterans Affairs Study to optimize the DEKA Arm.Prosthet Orthot Int. 2014 Dec;38(6):456-66. doi: 10.1177/0309364613506914. Epub 2013 Nov 28. Prosthet Orthot Int. 2014. PMID: 24286806
-
User and clinician perspectives on DEKA arm: results of VA study to optimize DEKA arm.J Rehabil Res Dev. 2014;51(1):27-38. doi: 10.1682/JRRD.2013.03.0068. J Rehabil Res Dev. 2014. PMID: 24805891
-
Controlling a multi-degree of freedom upper limb prosthesis using foot controls: user experience.Disabil Rehabil Assist Technol. 2014 Jul;9(4):318-29. doi: 10.3109/17483107.2013.822024. Epub 2013 Jul 31. Disabil Rehabil Assist Technol. 2014. PMID: 23902465
-
Update on advances in upper extremity prosthetics.J Hand Surg Am. 2011 Oct;36(10):1711-7. doi: 10.1016/j.jhsa.2011.07.024. J Hand Surg Am. 2011. PMID: 21971060 Review.
-
The quest for the bionic arm.J Am Acad Orthop Surg. 2014 Jun;22(6):346-51. doi: 10.5435/JAAOS-22-06-346. J Am Acad Orthop Surg. 2014. PMID: 24860130 Review.
Cited by
-
In-silico development and assessment of a Kalman filter motor decoder for prosthetic hand control.Comput Biol Med. 2021 May;132:104353. doi: 10.1016/j.compbiomed.2021.104353. Epub 2021 Mar 22. Comput Biol Med. 2021. PMID: 33831814 Free PMC article.
-
fNIRS-Based Upper Limb Motion Intention Recognition Using an Artificial Neural Network for Transhumeral Amputees.Sensors (Basel). 2022 Jan 18;22(3):726. doi: 10.3390/s22030726. Sensors (Basel). 2022. PMID: 35161473 Free PMC article.
-
Mechanical Design and Assessment of a Low-Cost 7-DOF Prosthetic Arm for Shoulder Disarticulation.Appl Bionics Biomech. 2018 Sep 3;2018:4357602. doi: 10.1155/2018/4357602. eCollection 2018. Appl Bionics Biomech. 2018. PMID: 30250502 Free PMC article.
-
Phantom-Mobility-Based Prosthesis Control in Transhumeral Amputees Without Surgical Reinnervation: A Preliminary Study.Front Bioeng Biotechnol. 2018 Nov 29;6:164. doi: 10.3389/fbioe.2018.00164. eCollection 2018. Front Bioeng Biotechnol. 2018. PMID: 30555823 Free PMC article.
-
Dielectric Elastomer Actuators, Neuromuscular Interfaces, and Foreign Body Response in Artificial Neuromuscular Prostheses: A Review of the Literature for an In Vivo Application.Adv Healthc Mater. 2021 Jul;10(13):e2100041. doi: 10.1002/adhm.202100041. Epub 2021 Jun 4. Adv Healthc Mater. 2021. PMID: 34085772 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical