Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2014 Mar;24(3):638-48.
doi: 10.1007/s00330-013-3046-0. Epub 2013 Oct 25.

Non-invasive evaluation of liver fibrosis: a comparison of ultrasound-based transient elastography and MR elastography in patients with viral hepatitis B and C

Affiliations
Clinical Trial

Non-invasive evaluation of liver fibrosis: a comparison of ultrasound-based transient elastography and MR elastography in patients with viral hepatitis B and C

Anneloes E Bohte et al. Eur Radiol. 2014 Mar.

Abstract

Objective: To compare the diagnostic accuracy of TE and MRE and establish cutoff levels and diagnostic strategies for both techniques, enabling selection of patients for liver biopsy.

Methods: One hundred three patients with chronic hepatitis B or C and liver biopsy were prospectively included. Areas under curves (AUROC) were compared for TE and MRE for METAVIR fibrosis grade ≥ F2 and ≥F3. We defined cutoff values for selection of patients with F0-F1 (sensitivity >95%) and for significant fibrosis F2-F4 (specificity >95%).

Results: Following exclusions, 85 patients were analysed (65 CHB, 19 CHC, 1 co-infected). Fibrosis stages were F0 (n = 3), F1 (n = 53), F2 (n = 15), F3 (n = 8) and F4 (n = 6). TE and MRE accuracy were comparable [AUROCTE ≥ F2: 0.914 (95% CI: 0.857-0.972) vs. AUROCMRE ≥ F2: 0.909 (0.840-0.977), P = 0.89; AUROCTE ≥ F3: 0.895 (0.816-0.974) vs. AUROCMRE ≥ F3: 0.928 (0.874-0.982), P = 0.42]. Cutoff values of <5.2 and ≥8.9 kPa (TE) and <1.66 and ≥2.18 kPa (MRE) diagnosed 64% and 66% of patients correctly as F0-F1 or F2-F4. A conditional strategy in inconclusive test results increased diagnostic yield to 80%.

Conclusion: TE and MRE have comparable accuracy for detecting significant fibrosis, which was reliably detected or excluded in two-thirds of patients. A conditional strategy further increased diagnostic yield to 80%.

Key points: • Both ultrasound-based transient elastography and magnetic resonance elastography can assess hepatic fibrosis. • Both have comparable accuracy for detecting liver fibrosis in viral hepatitis. • The individual techniques reliably detect or exclude significant liver fibrosis in 66 %. • A conditional strategy for inconclusive findings increases the number of correct diagnoses.

PubMed Disclaimer

References

    1. J Gastroenterol Hepatol. 2011 Aug;26(8):1318-25 - PubMed
    1. J Hepatol. 2010 Dec;53(6):1013-21 - PubMed
    1. Gut. 2007 Jul;56(7):968-73 - PubMed
    1. Hepatology. 1996 Aug;24(2):289-93 - PubMed
    1. Liver Int. 2012 Apr;32(4):622-8 - PubMed

Publication types

MeSH terms