Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Feb;46(2):139-43.
doi: 10.1055/s-0033-1344892. Epub 2013 Oct 25.

The ENKI-2 water-jet system versus Dual Knife for endoscopic submucosal dissection of colorectal lesions: a randomized comparative animal study

Affiliations
Comparative Study

The ENKI-2 water-jet system versus Dual Knife for endoscopic submucosal dissection of colorectal lesions: a randomized comparative animal study

Mihai Ciocîrlan et al. Endoscopy. 2014 Feb.

Abstract

Background and study aims: The ENKI-2 water-jet system for endoscopic submucosal dissection (ESD) combines submucosal saline pressure injection with dissection. The aim of this study was to compare ENKI-2 with a standard device in terms of procedure time and perforation rate during colorectal ESD.

Methods: In this randomized comparative study, 10 30-mm-diameter lesions were created in the colon and rectum of 10 healthy adult pigs. The ESD procedure time and perforation rates were recorded for the ENKI-2 system and a standard Dual Knife method. Each pig had half the lesions dissected by ENKI-2 and half dissected by Dual Knife. One experienced and one inexperienced endoscopist took part in the study.

Results: A total of 95 lesions were dissected (47 by ENKI-2 and 48 by Dual Knife). The experienced endoscopist was able to excise comparably sized 30-mm lesions using both techniques. The dissection time was shorter for ENKI-2 (18.9 vs. 25.6 minutes; P = 0.034) and the perforation rate was lower compared with the Dual Knife (one perforation [4 %] vs. nine perforations [36 %]; P = 0.011). The inexperienced endoscopist performed significantly larger dissections using the ENKI-2 (934 ± 405 mm2 vs. 673 ± 312 mm2; P = 0.021) despite pre-marking similarly sized artificial lesions. Multivariate analysis demonstrated that for all lesions the dissection time was significantly longer for lesions in the proximal colon (P = 0.001) and the distal colon (P < 0.0001) and shorter for the experienced operator (P < 0.0001). ENKI-2 shortened the dissection time, but not significantly (P = 0.093).

Conclusions: In experienced hands, the ENKI-2 system shortens dissection time and reduces the perforation rate. This effect was not statistically significant for an inexperienced operator. Dissection was faster in the rectum than the colon.