Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder
- PMID: 24163987
Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder
Abstract
Background: Atrial septal defect (ASD) is a common congenital heart disease in adults. Amplatzer septal occluder is one of the most common devices used for transcatheter closure due to its high success rate and ease to implant. Cocoon atrial septal occluder is a new nitinol-based device, its shape resembles Amplatzer septal occluder but coated with platinum to prevent nickel release. Little is known about clinical outcomes of large ASD closure using Cocoon atrial septal occluder
Objective: To review our experience in closure of secundum ASD in adults by Cocoon septal occluder and to compare the clinical outcomes and results of the patients who had ASD closure with a device greater than or equal to 30 mm and less than 30 mm.
Material and method: Between November 2005 and October 2008, 63 consecutive patients underwent transesophageal echocardiography (TEE)--guided transcatheter closure of secundum ASD. The patients were divided into two groups (Groups' 1 and 2) according to device diameter that is greater than or equal to 30 mm (n = 31) and less than 30 mm (n = 32), respectively. Clinical outcomes, complications, and transthoracic echocardiography (TTE) before hospital discharge, one to three months, and one-year were analyzed.
Results: Device implantations were successful in 27 patients (87.1%) in group 1 and 31 patients (96.9%) in group 2 (p = 0.196). The maximum size of secundum ASD in group 1 determined by TTE, TEE, and balloon sizing diameter (BSD) were 22.6 +/- 5.0 mm (range 15-32), 28.1 +/- 4.8 mm (range 19-39), and 31 +/- 3.5 mm (range 23-38) respectively. The maximum size of secundum ASD in group 2 determined by TTE, TEE, and BSD were 19.7 +/- 4.4 mm (range 12-31), 20.4 +/- 3.4 mm (range 13-26), and 23.1 +/- 2.9 mm (range 15-30) respectively. The mean device size in groups 1 and 2 were 33.5 +/- 3.1 mm and 24.6 +/- 3.3 mm, respectively. Four patients (12.9%) in group 1 had unsuccessful implantations. All of them were in the first 15 cases of using large device and two of them had device embolization requiring surgical removal. One patient (3.1%) in group 2 had an unsuccessful implantation and had device embolization requiring surgical removal. The patients in both groups gradually improved in clinical symptoms with decreased RVsystolic pressure and decreased RV size with complete ASD closure at one year
Conclusion: Transcatheter closure of large secundum ASD by Cocoon septal occluder is feasible with hemodynamic benefit. However complication rates are higher with large ASD closure with device size greater than or equal to 30 mm especially during the early "learning curve" period. With experience, the complication rate declines and the success rate is no different from the group with smaller device size.
Similar articles
-
Prospective randomized trial of transthoracic echocardiography versus transesophageal echocardiography for assessment and guidance of transcatheter closure of atrial septal defects in children using the Amplatzer septal occluder.JACC Cardiovasc Interv. 2013 Sep;6(9):974-80. doi: 10.1016/j.jcin.2013.05.007. JACC Cardiovasc Interv. 2013. PMID: 24050864 Clinical Trial.
-
[Transcatheter closure of secundum atrial septal defect in children].Zhonghua Er Ke Za Zhi. 2004 Apr;42(4):287-90. Zhonghua Er Ke Za Zhi. 2004. PMID: 15157392 Clinical Trial. Chinese.
-
Immediate and short-term outcomes after percutaneous atrial septal defect closure using the new nit-occlud ASD-R device.Catheter Cardiovasc Interv. 2014 Sep 1;84(3):464-70. doi: 10.1002/ccd.25434. Epub 2014 Feb 27. Catheter Cardiovasc Interv. 2014. PMID: 24677704
-
Fenestrated Transcatheter ASD Closure in Adults with Diastolic Dysfunction and/or Pulmonary Hypertension: Case Series and Review of the Literature.Congenit Heart Dis. 2016 Dec;11(6):663-671. doi: 10.1111/chd.12367. Epub 2016 Apr 29. Congenit Heart Dis. 2016. PMID: 27125263 Review.
-
Transcatheter Closure of Atrial Septal Defect: A Review of Currently Used Devices.Cureus. 2023 Jun 8;15(6):e40132. doi: 10.7759/cureus.40132. eCollection 2023 Jun. Cureus. 2023. PMID: 37425612 Free PMC article. Review.
Cited by
-
Safety and one-year follow-up analysis of percutaneous ASD closure at a tertiary care hospital.Indian Heart J. 2025 May-Jun;77(3):199-203. doi: 10.1016/j.ihj.2025.03.011. Epub 2025 Mar 27. Indian Heart J. 2025. PMID: 40157568 Free PMC article.
-
Transcatheter closure of secundum atrial septal defect using Cocoon septal occluder: immediate and long-term results.Egypt Heart J. 2022 Aug 13;74(1):59. doi: 10.1186/s43044-022-00298-2. Egypt Heart J. 2022. PMID: 35962873 Free PMC article.
-
Comparison of Transcatheter Atrial Septal Defect Closure in Children, Adolescents and adults: Differences, Challenges and Short-, Mid- and Long-Term Results.Korean Circ J. 2016 Nov;46(6):851-861. doi: 10.4070/kcj.2016.46.6.851. Epub 2016 Oct 20. Korean Circ J. 2016. PMID: 27826346 Free PMC article.
-
Cocoon devices for transcatheter closure of atrial septal defect and patent ductus arteriosus in children: Single center experience.Medicine (Baltimore). 2019 Mar;98(10):e14684. doi: 10.1097/MD.0000000000014684. Medicine (Baltimore). 2019. PMID: 30855458 Free PMC article.
-
Initial Experience with the Nit-Occlud ASD-R: Short-Term Results.Pediatr Cardiol. 2016 Oct;37(7):1258-65. doi: 10.1007/s00246-016-1426-3. Epub 2016 Jun 9. Pediatr Cardiol. 2016. PMID: 27278631