Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Dec;25(6):404-19.
doi: 10.1111/jerd.12063. Epub 2013 Oct 31.

The effect of a modeling resin and thermocycling on the surface hardness, roughness, and color of different resin composites

Affiliations

The effect of a modeling resin and thermocycling on the surface hardness, roughness, and color of different resin composites

Safa Tuncer et al. J Esthet Restor Dent. 2013 Dec.

Abstract

Statement of problem: The application of modeling resin could affect the surface quality and color of resin composites.

Purpose: To evaluate the effects of modeling resin on the microhardness, roughness, and color of composite restorations, with and without thermocycling.

Methods: Sixty disc-shaped specimens for each resin composite were prepared in three groups: Group 1: A resin composite disc was cured against a polyester matrix and finished/polished; Group 2: A composite instrument was wetted with Bisco Modeling Resin (Bisco, Schaumburg, IL, USA) to smooth the composite surface, which was cured against a polyester matrix and finished/polished; Group 3: A composite instrument was wetted with modeling resin to smooth the composite surface, which was cured against a polyester matrix. Microhardness, roughness, and color were measured 24 hours after curing and after 10,000 thermocycles.

Results: Modeling resin significantly influenced the microhardness of GrandioSO (Voco, Cuxhaven, Germany) and Gradia Direct Posterior (GC America, Alsip, IL, USA), and the surface roughness of GrandioSO, Filtek Silorane (3M ESPE, St Paul, MN, USA), and Aelite All Purpose Body (Bisco) (p < 0.05). The microhardness of the Group 1 resin composites was affected by thermocycling (p < 0.05); however, thermocycling had no significant effect on surface roughness (p > 0.05). Tested composites showed clinically perceptible color changes after thermocycling. In Group 1, Filtek Ultimate (3M ESPE) showed the lowest color change (p < 0.05), and in Group 2, Filtek Silorane showed the highest significant color changes (p < 0.05).

Conclusions: Modeling resin did not affect the microhardness, surface roughness, and color of Aelite LS Posterior (Bisco), Filtek Ultimate (3M ESPE), and Clearfil Majesty Esthetic (Kuraray Medical Inc, Tokyo, Japan) specimens. Also, thermocycling process only affected microhardness of tested resin composites.

Clinical significance: The effect of modeling resin on surface microhardness, roughness, and color stability of composite materials depends on the type of resin composite. In clinical practice, the adverse effects of modeling resin might be alleviated by a proper finishing and polishing procedure.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

Substances

LinkOut - more resources