Quantitation of neonicotinoid metabolites in human urine using GC-MS
- PMID: 24189204
- DOI: 10.1016/j.jchromb.2013.10.012
Quantitation of neonicotinoid metabolites in human urine using GC-MS
Abstract
A rapid and sensitive analytical method using gas chromatography-mass spectrometry (GC-MS) was developed for the measurement of neonicotinoid (NEO) metabolites 6-chloronicotinic acid (6CN), 2-chloro-1,3-thiazole-5-carboxylic acid (2CTCA) and 3-furoic acid (3FA) from human urine. After acid hydrolysis, the metabolites were extracted using solid phase extraction (SPE) column (Bond Elute Plexa PCX) and eluted with methanol. N,O-bis (trimethylsilyl) trifluoroacetamide with 1% trimethylchlorosilane (BSTFA-TMCS, 99:1) was used for the derivatization of metabolites and analyzed by GC-MS with the electron ionization mode. The elution solvent, derivatization reagent and its conditions were mainly optimized for improved detection and quantitation of the metabolites based on signal-to-noise ratio, recoveries and reproducibility. Our present method offered a sufficiently low limit of detection (0.1μg/L for each metabolite) with satisfactory within-run and between-day accuracy and precision (variability less than 12.3%, R.S.D). This method is simple, sensitive and precise, and has been successfully applied to quantify low concentrations of urinary 6CN, 2CTCA and 3FA for the occupational NEO exposures survey.
Keywords: GC-MS; Metabolite; Neonicotinoid; Urine.
Copyright © 2013 Elsevier B.V. All rights reserved.
Similar articles
-
GC-MS method for the simultaneous determination of β-blockers, flavonoids, isoflavones and their metabolites in human urine.J Pharm Biomed Anal. 2011 Aug 25;56(1):93-102. doi: 10.1016/j.jpba.2011.04.024. Epub 2011 May 5. J Pharm Biomed Anal. 2011. PMID: 21601407
-
A sensitive and efficient procedure for the high-throughput determination of nine urinary metabolites of pyrethroids by GC-MS/MS and its application in a sample of Japanese children.Anal Bioanal Chem. 2018 Sep;410(24):6207-6217. doi: 10.1007/s00216-018-1229-x. Epub 2018 Jul 26. Anal Bioanal Chem. 2018. PMID: 30046868
-
Comprehensive profiling analysis of bioamines and their acidic metabolites in human urine by gas chromatography/mass spectrometry combined with selective derivatization.J Chromatogr A. 2013 Aug 30;1305:234-43. doi: 10.1016/j.chroma.2013.07.003. Epub 2013 Jul 4. J Chromatogr A. 2013. PMID: 23890555
-
[Determination of ethyl glucuronide in human urine by solid phase extraction-gas chromatography-mass spectrometry].Se Pu. 2011 Feb;29(2):172-5. doi: 10.3724/sp.j.1123.2011.00172. Se Pu. 2011. PMID: 21598520 Chinese.
-
Simultaneous quantitation of seven pyrethroid metabolites in human urine by capillary gas chromatography-mass spectrometry.J Sep Sci. 2013 Feb;36(4):773-80. doi: 10.1002/jssc.201200655. Epub 2012 Dec 15. J Sep Sci. 2013. PMID: 23255469
Cited by
-
A critical review on the potential impacts of neonicotinoid insecticide use: current knowledge of environmental fate, toxicity, and implications for human health.Environ Sci Process Impacts. 2020 Jun 24;22(6):1315-1346. doi: 10.1039/c9em00586b. Environ Sci Process Impacts. 2020. PMID: 32267911 Free PMC article. Review.
-
Human metabolism and urinary excretion of seven neonicotinoids and neonicotinoid-like compounds after controlled oral dosages.Arch Toxicol. 2022 Jan;96(1):121-134. doi: 10.1007/s00204-021-03159-0. Epub 2021 Oct 13. Arch Toxicol. 2022. PMID: 34642770 Free PMC article.
-
Promotional Consideration: A Potential Mechanistic Link between Neonicotinoid Insecticides and Hormone-Dependent Breast Cancer.Environ Health Perspect. 2018 Nov;126(11):114001. doi: 10.1289/EHP4097. Environ Health Perspect. 2018. PMID: 30499692 Free PMC article. No abstract available.
-
Quantification of DEET and neonicotinoid pesticide biomarkers in human urine by online solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry.Anal Bioanal Chem. 2019 Jan;411(3):669-678. doi: 10.1007/s00216-018-1481-0. Epub 2018 Nov 28. Anal Bioanal Chem. 2019. PMID: 30483854 Free PMC article.
-
Variability in urinary neonicotinoid concentrations in single-spot and first-morning void and its association with oxidative stress markers.Environ Int. 2020 Feb;135:105415. doi: 10.1016/j.envint.2019.105415. Epub 2019 Dec 21. Environ Int. 2020. PMID: 31869729 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous