Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1996 Nov;43(2):181-8.
doi: 10.1007/BF00398606.

The efficacy of protoporphyrin as a predictive biomarker for lead exposure in canvasback ducks: Effect of sample storage time

Affiliations

The efficacy of protoporphyrin as a predictive biomarker for lead exposure in canvasback ducks: Effect of sample storage time

J Christian Franson et al. Environ Monit Assess. 1996 Nov.

Abstract

We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.

PubMed Disclaimer

Similar articles

References

    1. Environ Monit Assess. 1994 Feb;29(3):267-88 - PubMed
    1. Clin Chem. 1975 Jan;21(1):93-7 - PubMed
    1. Vet Rec. 1983 Jul 16;113(3):65-6 - PubMed
    1. Comp Biochem Physiol C Comp Pharmacol Toxicol. 1985;80(2):431-9 - PubMed
    1. Arch Environ Contam Toxicol. 1988 Jan;17(1):121-30 - PubMed