Diagnostic accuracy of computer tomography angiography and magnetic resonance angiography in the stenosis detection of autologuous hemodialysis access: a meta-analysis
- PMID: 24194928
- PMCID: PMC3806799
- DOI: 10.1371/journal.pone.0078409
Diagnostic accuracy of computer tomography angiography and magnetic resonance angiography in the stenosis detection of autologuous hemodialysis access: a meta-analysis
Abstract
Purpose: To compare the diagnostic performances of computer tomography angiography (CTA) and magnetic resonance angiography (MRA) for detection and assessment of stenosis in patients with autologuous hemodialysis access.
Materials and methods: Search of PubMed, MEDLINE, EMBASE and Cochrane Library database from January 1984 to May 2013 for studies comparing CTA or MRA with DSA or surgery for autologuous hemodialysis access. Eligible studies were in English language, aimed to detect more than 50% stenosis or occlusion of autologuous vascular access in hemodialysis patients with CTA and MRA technology and provided sufficient data about diagnosis performance. Methodological quality was assessed by the Quality Assessment of Diagnostic Studies (QUADAS) instrument. Sensitivities (SEN), specificities (SPE), positive likelihood ratio (PLR), negative likelihood values (NLR), diagnostic odds ratio (DOR) and areas under the receiver operator characteristic curve (AUC) were pooled statistically. Potential threshold effect, heterogeneity and publication bias was evaluated. The clinical utility of CTA and MRA in detection of stenosis was also investigated.
Result: Sixteen eligible studies were included, with a total of 500 patients. Both CTA and MRA were accurate modality (sensitivity, 96.2% and 95.4%, respectively; specificity, 97.1 and 96.1%, respectively; DOR [diagnostic odds ratio], 393.69 and 211.47, respectively) for hemodialysis vascular access. No significant difference was detected between the diagnostic performance of CTA (AUC, 0.988) and MRA (AUC, 0.982). Meta-regression analyses and subgroup analyses revealed no statistical difference. The Deek's funnel plots suggested a publication bias.
Conclusion: Diagnostic performance of CTA and MRA for detecting stenosis of hemodialysis vascular access had no statistical difference. Both techniques may function as an alternative or an important complement to conventional digital subtraction angiography (DSA) and may be able to help guide medical management.
Conflict of interest statement
Figures
Similar articles
-
Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography.J Vasc Surg. 2005 Oct;42(4):739-46. doi: 10.1016/j.jvs.2005.06.006. J Vasc Surg. 2005. PMID: 16242563
-
Diagnostic accuracy of colour Doppler ultrasonography, CT angiography and blood-pool-enhanced MR angiography in assessing carotid stenosis: a comparative study with DSA in 170 patients.Radiol Med. 2012 Feb;117(1):54-71. doi: 10.1007/s11547-011-0651-3. Epub 2011 Mar 7. Radiol Med. 2012. PMID: 21424318 English, Italian.
-
Role of non-contrast balanced steady-state free precession megnetic resonance angiography compared to contrast-enhanced megnetic resonance angiography in diagnosing renal artery stenosis: a meta-analysis.Chin Med J (Engl). 2014;127(19):3483-90. Chin Med J (Engl). 2014. PMID: 25269918
-
Meta-analysis of computed tomography angiography versus magnetic resonance angiography for intracranial aneurysm.Medicine (Baltimore). 2018 May;97(20):e10771. doi: 10.1097/MD.0000000000010771. Medicine (Baltimore). 2018. PMID: 29768368 Free PMC article. Review.
-
Gadolinium-enhanced magnetic resonance versus computed tomography angiography for renal artery stenosis: A systematic review and meta-analysis.J Formos Med Assoc. 2021 May;120(5):1171-1178. doi: 10.1016/j.jfma.2021.01.007. Epub 2021 Feb 12. J Formos Med Assoc. 2021. PMID: 33583703
Cited by
-
CT and MR imaging of the upper extremity vasculature: pearls, pitfalls, and challenges.Cardiovasc Diagn Ther. 2019 Aug;9(Suppl 1):S152-S173. doi: 10.21037/cdt.2018.09.15. Cardiovasc Diagn Ther. 2019. PMID: 31559161 Free PMC article. Review.
-
Diagnostic accuracy of magnetic resonance angiography for Budd-Chiari syndrome: A meta-analysis.Exp Ther Med. 2018 Dec;16(6):4873-4878. doi: 10.3892/etm.2018.6764. Epub 2018 Sep 19. Exp Ther Med. 2018. PMID: 30542443 Free PMC article.
-
Revisiting the risks of MRI with Gadolinium based contrast agents-review of literature and guidelines.Insights Imaging. 2015 Oct;6(5):553-8. doi: 10.1007/s13244-015-0420-2. Epub 2015 Aug 8. Insights Imaging. 2015. PMID: 26253982 Free PMC article.