. 2014 Jan 1;189(1):48-56.
doi: 10.1164/rccm.201306-1088OC.

Humidifier disinfectant-associated children's interstitial lung disease

Affiliations

Humidifier disinfectant-associated children's interstitial lung disease

Kyung Won Kim et al. Am J Respir Crit Care Med. .

Abstract

Rationale: Beginning in 2006, epidemics of a fatal lung injury of unknown cause in children were observed in Korea every spring. A recent study demonstrated that this type of children's interstitial lung disease (chILD) is associated with humidifier disinfectant use.

Objectives: To determine the clinical characteristics of this type of chILD and to assess whether the nationwide suspension of humidifier disinfectant sales in the autumn of 2011 affected its incidence.

Methods: The clinical characteristics of suspected cases between 2006 and 2011 were determined by a nationwide retrospective study. The potential causal relationship with humidifier disinfectants was examined by a prospective surveillance study after humidifier disinfectant sales were suspended.

Measurements and main results: In total, 138 children were diagnosed with this type of chILD, which was characterized by rapid progression, high mortality, predominance in the spring season, and a familial tendency. The annual incidence increased in 2011 and then dropped to zero in 2012. The children were on average 30.4 months old. The most frequent symptoms at admission were cough and dyspnea. As the disease progressed, the typical complication was spontaneous air leak. Eighty children (58%) died. Two years after humidifier disinfectant-sale suspension, no more new cases were found.

Conclusions: This study suggests that humidifier disinfectant inhalation causes an idiopathic type of chILD that is characterized by spontaneous air leak, rapid progression, lack of response to treatment, and high mortality. Further safety studies must be performed on common environmental compounds, particularly those that enter the human body by an unusual route.

PubMed Disclaimer

Comment in

  • Humidifier and environmental "chILD" risks.
    Deterding RR, White CW. Deterding RR, et al. Am J Respir Crit Care Med. 2014 Jan 1;189(1):10-2. doi: 10.1164/rccm.201311-2050ED. Am J Respir Crit Care Med. 2014. PMID: 24381989 No abstract available.

Publication types

LinkOut - more resources