Methods for non-invasive detection of ventricular late potentials--a comparative multicenter study
- PMID: 2420596
- DOI: 10.1093/oxfordjournals.eurheartj.a061953
Methods for non-invasive detection of ventricular late potentials--a comparative multicenter study
Abstract
To evaluate the methodological problems of the non-invasive registration of late potentials the results obtained with four different averaging devices in the same 109 patients were compared. The high-resolution ECG was obtained from the body surface, high-gain amplified and filtered. With the averaging technique, the improved signal-to-noise ratio was able to detect low-amplitude cardiac activity. The incidence of late potentials detected with the four averaging systems, whose characteristics are described, ranged between 12% and 21%. Corresponding positive results were obtained in 5.5%, corresponding negative results in 68.8%. The reasons for differing results were mainly due to differences in visual or automatic interpretation of the registered fractionated electrical cardiac activity. Additionally, the determination of the end of QRS using the QRS width, obtained from reference leads, may influence the specificity of the methods.
Similar articles
-
[Use of a Soviet-made device for recording late ventricular potentials].Kardiologiia. 1991 Dec;31(12):71-4. Kardiologiia. 1991. PMID: 1726180 Russian.
-
Beat-to-beat detection of ventricular late potentials with high-resolution electrocardiography.Am Heart J. 1991 Feb;121(2 Pt 1):576-85. doi: 10.1016/0002-8703(91)90728-z. Am Heart J. 1991. PMID: 1990764
-
Late potentials and arrhythmogenesis.Pacing Clin Electrophysiol. 1985 May;8(3 Pt 1):440-62. doi: 10.1111/j.1540-8159.1985.tb05784.x. Pacing Clin Electrophysiol. 1985. PMID: 2582395
-
[Methods for the detection of ventricular late potentials. High amplification ECG, signal averaging technic, frequency analysis and intracardiac mapping].Herz. 1988 Jun;13(3):147-59. Herz. 1988. PMID: 3042571 Review. German.
-
Intraventricular aberrancy versus ventricular ectopy.Cardiovasc Clin. 1973;5(3):35-86. Cardiovasc Clin. 1973. PMID: 4135233 Review. No abstract available.
Cited by
-
Fast and reliable QRS alignment technique for high-frequency analysis of signal-averaged ECG.Med Biol Eng Comput. 1993 Jul;31 Suppl:S137-46. doi: 10.1007/BF02446662. Med Biol Eng Comput. 1993. PMID: 8231317
-
[Spectral analysis of the ECG for detecting late potentials as risk factors of life-threatening cardiac arrhythmias].Klin Wochenschr. 1990 Aug 2;68(15):744-9. doi: 10.1007/BF01647242. Klin Wochenschr. 1990. PMID: 2214599 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources