Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014:120:499-504.
doi: 10.1016/j.saa.2013.10.035. Epub 2013 Oct 20.

Fast determination of two atractylenolides in Rhizoma Atractylodis Macrocephalae by Fourier transform near-infrared spectroscopy with partial least squares

Affiliations

Fast determination of two atractylenolides in Rhizoma Atractylodis Macrocephalae by Fourier transform near-infrared spectroscopy with partial least squares

Qing-Song Shao et al. Spectrochim Acta A Mol Biomol Spectrosc. 2014.

Abstract

Rhizoma Atractylodis Macrocephalae (RAM) is a commonly used food and traditional Chinese medicine (TCM), which traditionally strengthens the spleen, benefits vital energy, eliminates dampness, and promotes hidroschesis. Its primary effective constituents are polysaccharides and volatile oil, whose main components are atractylenolide I and III. Fourier transform near-infrared spectroscopy (FT-NIR) is widely used in TCM research. However, determination of atractylenolides in RAM using FT-NIR has not been described. In this study, a new method for the determination of atractylenolides I and III in RAM by NIR was established. The spectral characteristics of atractylenolides I and III were obtained by second derivative multiple scattering correction, and its chart to the original absorbance spectra. Additionally, in combination with the partial least squares (PLS) algorithm, the calibration process was performed for the quantitation of the samples. The root mean square error of cross-validation of the PLS models for atractylenolides I and III was 0.0387 and 0.0358, and the determination coefficient of quantitative models was 96.63 and 96.16, respectively. This study demonstrated that NIR spectroscopy can be used to analyze quickly and efficiently the contents of atractylenolides I and III in RAM.

Keywords: Atractylenolide I; Atractylenolide III; FT-NIR; Partial least squares method; Rhizoma Atractylodis Macrocephalae.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources