. 2015 May;23(5):1429-1433.
doi: 10.1007/s00167-013-2772-9. Epub 2013 Nov 12.

Outcome of arthroscopic treatment for displaced lateral clavicle fractures using a double button device

Affiliations

Outcome of arthroscopic treatment for displaced lateral clavicle fractures using a double button device

Philippe Loriaut et al. Knee Surg Sports Traumatol Arthrosc. 2015 May.

Abstract

Purpose: The purpose of this study was to assess the clinical and radiological outcomes of an arthroscopically assisted fixation of type IIB fractures using a double button device.

Methods: Twenty-one patients with a type IIB displaced fracture of the clavicle who received an arthroscopically assisted fixation using a double button device were enrolled from 2009 to 2011. Clinical assessment included the patient's demographics, cause of injury, delay before surgery, time for surgery, time before resuming work and sports, the Shoulder and Hand (QuickDASH) score, the Constant-Murley score and the visual pain analogue scale (VAS). Radiological examination consisted of anteroposterior and axillary radiographs.

Results: The median age of patients was 33 years (range 18-67). Mean follow-up was 35 ± 8.9 months (range 24-51 months). The average delay before surgery was 3 days (range 1-7). At final follow-up, the mean QuickDASH score, Constant score and VAS were respectively 3.2 ± 6 (range 0-25), 94.8 ± 9.9 (range 62-100) and 0.5 ± 1.2 (range 0-4). Seventeen (81 %) patients were able to resume work, including heavy manual labour, and to resume their sport activities as well. Postoperative complications included one transient adhesive capsulitis, a symptomatic acromioclavicular joint osteoarthritis and an implant failure with nonunion. Bony union was achieved in all other patients.

Conclusion: This study has demonstrated that the arthroscopic treatment using a double button device was effective at providing a satisfactory functional outcome, minimizing the risk of complications and presenting low implant failure and low nonunion rates in patients with Neer type IIB fractures of the distal clavicle. Such results lead us to consider this minimally invasive technique as a first-choice treatment.

Level of evidence: IV.

PubMed Disclaimer

References

    1. Anderson K (2003) Evaluation and treatment of distal clavicle fractures. Clin Sports Med 22:319–326 - DOI - PubMed
    1. Ballmer FT, Gerber C (1991) Coracoclavicular screw fixation for unstable fractures of the distal clavicle: a report of five cases. J Bone Joint Surg Br 73:291–294 - PubMed
    1. Baumgarten KM (2008) Arthroscopic fixation of a type II-variant, unstable distal clavicle fracture. Orthopedics 31:1938–2367 - DOI
    1. Bhatia DN, Page RS (2012) Surgical treatment of lateral clavicle fractures associated with complete coracoclavicular ligament disruption: clinico-radiological outcomes of acromioclavicular joint sparing and spanning implants. Int J Shoulder Surg 6:116–120 - DOI - PMC - PubMed
    1. Beaton DE, Wright JG, Katz JN (2005) Development of the QuickDash: comparison of three item-reduction approaches. J Bone Joint Surg Am 87:1038–1046 - DOI - PubMed