Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Apr;6(4):257-63.
doi: 10.1016/1044-0305(95)00025-9.

Design and performance of an in-line surface-induced dissociation device in a four-sector mass spectrometer

Affiliations

Design and performance of an in-line surface-induced dissociation device in a four-sector mass spectrometer

K L Scheycor et al. J Am Soc Mass Spectrom. 1995 Apr.

Abstract

A new in-line surface-induced dissociation device has been designed and characterized in a high performance four-sector tandem mass spectrometer. The design incorporates a target electrode parallel to the ion beam axis and an angled deflector plate (45° relative to the ion beam) to provide large collision angles. In addition, an extraction electrode (parallel to the target electrode) is employed to efficiently extract product ions from the target surface. Results obtained with this device indicate high internal energy deposition (up to 16. 3 eV) as measured with the thermometer ions W(CO) 6 (+·) and Si(C2H5)4/+·, as evidenced by extensive dissociation of the refractory pyrene molecular ion, and as indicated by the b 3/y 2 ratio in the product ion spectrum of leucine enkephalin. High resolution provided by the four-sector instrument for both precursor ions and product ions allows the observation of previously unobserved dissociation products in the surface-induced dissociation spectra of Si(C2H5)4/+· and novel ion-surface reaction products in spectra of W(CO)6/+· ions after collisions with hydrocarbon-covered surfaces. Both hydrogen atom and hydrocarbon abstraction products are observed. The dissociation efficiencies measured with the in-line device are approximately 1% when hydrocarbon-coated surfaces are used and increase fivefold with a fluorinated surface.

PubMed Disclaimer

References

    1. J Am Soc Mass Spectrom. 1992 Jul;3(5):487-92 - PubMed
    1. Anal Chem. 1990 Jul 1;62(13):1295-9 - PubMed
    1. J Am Soc Mass Spectrom. 1993 Oct;4(10):769-73 - PubMed
    1. Anal Chem. 1993 Oct 15;65(20):2859-72 - PubMed
    1. J Am Soc Mass Spectrom. 1991 Dec;2(6):487-91 - PubMed

LinkOut - more resources