Unpredictability of blood pressures recorded outside the clinic in the treated hypertensive patient
- PMID: 2422472
- DOI: 10.1097/00005344-198603000-00016
Unpredictability of blood pressures recorded outside the clinic in the treated hypertensive patient
Abstract
Ambulatory blood pressure profiles were obtained with the Remler M2000, a portable semiautomatic blood pressure recorder, in 38 chronically treated hypertensive patients who continued to have blood pressures measured by their physician greater than 140 mm Hg systolic and greater than 89 mm Hg diastolic. On the average, ambulatory recorded blood pressures were significantly lower (151/94 +/- 26/13 mm Hg; mean +/- SD) than those determined at the clinic not only by a physician (179/109 +/- 22/11 mm Hg), but by a nurse (163/101 +/- 24/10 mm Hg). Individual mean recorded ambulatory blood pressures could be predicted neither from office readings obtained by a physician nor from those measured by a nurse. Because of this unpredictability of blood pressures prevailing outside the clinic, ambulatory blood pressure monitoring seems to be very useful, if not necessary, in assessing the efficacy of antihypertensive drugs. By this technique, it may be possible to select patients who do not need a change of treatment although their blood pressure levels remain persistently elevated in the physician's office.
Similar articles
-
Ambulatory blood pressure recordings. Reproducibility and unpredictability.Hypertension. 1984 May-Jun;6(3):C110-5. Hypertension. 1984. PMID: 6735450
-
Ambulatory blood pressure recordings. Reproducibility and unpredictability.Hypertension. 1984 Jan-Feb;6(1):110-4. Hypertension. 1984. PMID: 6693140
-
Ambulatory blood pressure measurement and antihypertensive therapy.J Hypertens Suppl. 1989 May;7(3):S33-9. J Hypertens Suppl. 1989. PMID: 2668463 Clinical Trial.
-
Blood pressure monitoring outside the office for the evaluation of patients with resistant hypertension.Hypertension. 1988 Mar;11(3 Pt 2):II96-100. doi: 10.1161/01.hyp.11.3_pt_2.ii96. Hypertension. 1988. PMID: 3280500 Review.
-
Portable blood pressure monitoring for borderline or mild hypertension during pregnancy.Clin Obstet Gynecol. 1992 Jun;35(2):395-401. Clin Obstet Gynecol. 1992. PMID: 1638830 Review.
Cited by
-
Effects of prolonged administration of the angiotensin converting enzyme inhibitor CGS 16617 in normotensive volunteers.Eur J Clin Pharmacol. 1989;36(6):587-91. doi: 10.1007/BF00637741. Eur J Clin Pharmacol. 1989. PMID: 2550244 Clinical Trial.
-
Doctors record higher blood pressures than nurses: systematic review and meta-analysis.Br J Gen Pract. 2014 Apr;64(621):e223-32. doi: 10.3399/bjgp14X677851. Br J Gen Pract. 2014. PMID: 24686887 Free PMC article.
-
Use of ambulatory blood pressure monitoring in the management of antihypertensive therapy.Drugs. 1992;44 Suppl 1:12-6. doi: 10.2165/00003495-199200441-00003. Drugs. 1992. PMID: 1283574 Clinical Trial.
-
Double-blind, randomized comparative study of the antihypertensive effect of nicardipine slow-release and nifedipine slow-release in hypertensive patients with coronary heart disease.Cardiovasc Drugs Ther. 1991 Jun;5(3):647-54. doi: 10.1007/BF03029734. Cardiovasc Drugs Ther. 1991. PMID: 1878335 Clinical Trial.
-
Noninvasive, automatic 24-h ambulatory blood pressure monitoring in normotensive subjects.Eur J Appl Physiol Occup Physiol. 1987;56(4):381-3. doi: 10.1007/BF00417763. Eur J Appl Physiol Occup Physiol. 1987. PMID: 3622479
Publication types
MeSH terms
LinkOut - more resources
Medical