Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jun;80(6):655-65.
Epub 2013 Nov 13.

A pharmacokinetic study of 48-hour sevoflurane inhalation using a disposable delivery system (AnaConDa®) in ICU patients

Affiliations
  • PMID: 24226486
Free article

A pharmacokinetic study of 48-hour sevoflurane inhalation using a disposable delivery system (AnaConDa®) in ICU patients

S Perbet et al. Minerva Anestesiol. 2014 Jun.
Free article

Abstract

Background: Little is known regarding sevoflurane kinetics and toxicity during long-term sedation of intensive care unit (ICU) patients using the AnaConDa® system. The objective of the present study was to establish a pharmacokinetic description of 48-h sevoflurane administration, and to estimate plasma concentrations of metabolites.

Methods: Forty-eight hour sedation with sevoflurane vaporized via an AnaConDa® device, with an end-tidal concentration objective of 1.5% (v/v), was initiated in 12 non-obese patients who did not have hepatic or renal failure but who required sedation for more than 48 h in our ICU. Plasma sevoflurane, hexafluoroisopropanol, and fluoride concentrations were determined over this time period and pharmacokinetic analysis was performed.

Results: The mean plasma concentration of sevoflurane was 76 mg/L at 24 h and 70 mg/L at 48 h. Wash-out of plasma sevoflurane correlated with a rapid decrease in the mean end-tidal sevoflurane level. The mean free plasma fraction of hexafluoroisopropanol never exceeded 8 mg/mL. The mean fluoride concentration was 0.8 µmol/L on day 0, 51.7 µmol/L on day 1, and 68.1 µmol/L on day 2 (P<0.0001). The distribution volume was 53 L, the elimination constant 2.9 h-1, the transfer constant from compartment 1 to compartment 2 (K1-2) 1.2 h-1, the K2-1 0.26 h-1, the half-life of elimination 3.78 h, and the total clearance 156 L/h.

Conclusion: Following 48 hours of sedation using sevoflurane inhalation administered using an AnaConDa® delivery device, sevoflurane washout was rapid. Plasma fluoride levels accumulated over the study period without apparent nephrotoxicity.

PubMed Disclaimer

LinkOut - more resources