Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1986 Jun;23(6):1072-7.
doi: 10.1128/jcm.23.6.1072-1077.1986.

Detection of human T-cell lymphotropic virus type III-related antigens and anti-human T-cell lymphotropic virus type III antibodies by anticomplementary immunofluorescence

Comparative Study

Detection of human T-cell lymphotropic virus type III-related antigens and anti-human T-cell lymphotropic virus type III antibodies by anticomplementary immunofluorescence

R S Blumberg et al. J Clin Microbiol. 1986 Jun.

Abstract

Techniques presently available for detection of human T-cell lymphotropic virus type III (HTLV-III) antigens and antibodies are laborious or relatively nonsensitive. We adapted anticomplementary immunofluorescence (ACIF) for these purposes. In HTLV-III-infected cells, specific ACIF was demonstrated by a diffuse speckling pattern that often resulted in a peripheral cellular rim of fluorescence. A 97% concordance was demonstrated between the ACIF assay and other sensitive tests for HTLV-III antibody detection (Western blot and membrane immunofluorescence and fixed-cell immunofluorescence tests). The ACIF assay was both more sensitive and more specific when compared with the enzyme-linked immunosorbent assay. For detection of HTLV-III antigens, the ACIF assay appeared to be as sensitive as the reverse transcriptase assay and more sensitive, with less background reactivity, than the conventional immunofluorescence assay. The ACIF assay often detected low levels of HTLV-III antigens within 3 days of infection in vitro, compared with 5 to 7 days with the indirect immunofluorescence assay, and generally paralleled the reverse transcriptase assay. The ACIF assay is a simple, sensitive, and specific assay for detection of HTLV-III-related antigens and antibodies. It should prove useful in the diagnosis of HTLV-III infection, as well as in studies of pathogenesis.

PubMed Disclaimer

References

    1. Nature. 1974 Apr 5;248(448):521-2 - PubMed
    1. J Clin Microbiol. 1980 Oct;12(4):562-5 - PubMed
    1. J Immunol. 1966 Jun;96(6):936-43 - PubMed
    1. J Immunol. 1981 Jun;126(6):2114-6 - PubMed
    1. Science. 1984 Aug 24;225(4664):840-2 - PubMed

Publication types

MeSH terms