Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1991 Jan;2(1):22-8.
doi: 10.1016/1044-0305(91)80057-E.

Investigation of UV matrix-assisted laser desorption fourier transform mass spectrometry for peptides

Affiliations

Investigation of UV matrix-assisted laser desorption fourier transform mass spectrometry for peptides

R L Hettich et al. J Am Soc Mass Spectrom. 1991 Jan.

Abstract

Analytical Chemistry Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA Ultraviolet matrix-assisted laser desorption can be used to enhance formation of [M + H](+), [M + Na](+), and [M + K)(+) ions from small peptides for Fourier transform mass spectrometry (FTMS). In accord with laser desorption (LD) time-of-flight experiments, matrices such as nicotinic acid and 2-pyrazinecarboxylic acid exhibit strong enhancement effects (i.e., formation of abundant protonated and cationized molecules for the analyte with virtually no fragment ions) for 266 nm LD/FTMS, whereas pyrazinedicarboxylic acid provides no matrix enhancement at this wavelength. Both sinapinic acid and coumarin-120 provide strong matrix enhancement effects for the 355-nm LD of peptides. For the small peptides examined in this study, no significant differences in the abundance of fragment ions were observed between the 266- and 355-nm wavelengths. Matrix-assisted LD/FTMS is useful for the generation and characterization of ions corresponding to protonated and cationized molecules from virtually all biological compounds with molecular weights up to 2000. The lack of observation of biological ions with m/ z > 2500 may be related to inefficient trapping of these laser-desorbed ions or instrumental detection limitations of FTMS and is under further investigation.

PubMed Disclaimer

References

    1. Anal Chem. 1988 Oct 15;60(20):2299-301 - PubMed
    1. Proc Natl Acad Sci U S A. 1985 Oct;82(19):6367-70 - PubMed
    1. Rapid Commun Mass Spectrom. 1989 Jul;3(7):233-7 - PubMed
    1. Anal Chem. 1990 Apr 15;62(8):878-80 - PubMed
    1. Proc Natl Acad Sci U S A. 1987 Feb;84(3):620-3 - PubMed

LinkOut - more resources