Observational Study
. 2014 Mar;59(3):653-7.
doi: 10.1007/s10620-013-2934-0. Epub 2013 Nov 20.

Impact of water exchange colonoscopy on serum sodium and potassium levels: an observational study

Affiliations
Observational Study

Impact of water exchange colonoscopy on serum sodium and potassium levels: an observational study

Joseph W Leung et al. Dig Dis Sci. 2014 Mar.

Abstract

Background: Concerns over the hypothetical adverse effects of water absorption and the disturbance of serum sodium and potassium levels prompted a quality assurance evaluation of water exchange (WE) colonoscopy.

Aim: The purpose of this study was to evaluate the balance of water infused and suctioned in WE colonoscopy, and to quantify the acute impact on serum levels of sodium and potassium.

Methods: Prospectively collected quality monitoring data of patients undergoing screening and surveillance colonoscopy at the Sacramento Veterans Affairs Medical Center were analyzed. Measurements were made of volume infused and suctioned during, and blood samples drawn 10 min before the start of and 10 min after completion of WE colonoscopy. Outcome measures included volume of water infused and suctioned, and serum levels of sodium and potassium.

Results: A total of 140 patients (134M:6F), mean age of 59, underwent WE colonoscopy. Mean total volume of water infused was 1,839 mL. A negative balance of an average of 22 mL was documented. The mean (standard deviation) values (in meq/L) of serum levels of sodium 139.33 (2.27) and 139.28 (2.32), and potassium 3.86 (0.36) and 3.91 (0.39), before and after colonoscopy, respectively, showed no significant change.

Conclusion: The WE method allowed most of the water infused during colonoscopy to be recovered by suction at the completion of colonoscopy. Serum sodium and potassium levels did not change significantly within 10 min after completion. The WE method appears to be safe with minimal water retention and is devoid of acute fluctuations in serum levels of sodium and potassium.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Gastrointest Endosc. 2011 Jan;73(1):103-10 - PubMed
    1. J Interv Gastroenterol. 2012 Jul;2(3):106-111 - PubMed
    1. Gastrointest Endosc. 2009 Sep;70(3):505-10 - PubMed
    1. Gastrointest Endosc. 2010 Oct;72(4):693-700 - PubMed
    1. Aliment Pharmacol Ther. 2007 Aug 15;26(4):627-31 - PubMed

Publication types

LinkOut - more resources