Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Mar;98(3):350-5.
doi: 10.1136/bjophthalmol-2013-304152. Epub 2013 Nov 25.

Retinal thinning and correlation with functional disability in patients with Parkinson's disease

Affiliations

Retinal thinning and correlation with functional disability in patients with Parkinson's disease

M Satue et al. Br J Ophthalmol. 2014 Mar.

Abstract

Aims: To determine whether there is an association between retinal thinning and functional rating scales in patients with Parkinson's disease (PD).

Materials and methods: Patients with PD (n=153) and controls (n=242) underwent evaluations of the macula and retinal nerve fibre layer (RNFL) using two new-generation Fourier domain optical coherence tomography (OCT) devices (Cirrus, Carl Zeiss Meditec, Dublin, California, USA; Spectralis, Heidelberg Engineering, Heidelberg, Germany). PD severity was assessed using the Schwab-England Activities of Daily Living scale, the Unified Parkinson Disease Rating Scale, the Hoehn and Yahr (HY) scale. Retinal and RNFL thicknesses were compared between patients and controls. Correlations between structural parameters and the scores of the neurologic scales were evaluated.

Results: RNFL parameters were significantly reduced in patients with PD, especially when using the Spectralis OCT device. All macular parameters, except for foveal thickness, differed significantly between controls and patients with PD (p<0.001). HY scores were significantly and inversely correlated with all macular parameters when measured with the Spectralis OCT device (p<0.05) and with RNFL thickness when measured with the Cirrus OCT device (nasal quadrant, sectors 2 and 5).

Conclusions: The neurodegeneration caused by PD can be detected using Fourier domain OCT. RNFL and macular thicknesses correlate with PD severity.

Keywords: Optic Nerve; Pathology; Retina.