Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
- PMID: 24285286
- DOI: 10.1093/rpd/nct304
Overview of the ICRP/ICRU adult reference computational phantoms and dose conversion coefficients for external idealised exposures
Abstract
This paper reviews the ICRP Publications 110 and 116 describing the reference computational phantoms and dose conversion coefficients for external exposures. The International Commission on Radiological Protection (ICRP) in its 2007 Recommendations made several revisions to the methods of calculation of the protection quantities. In order to implement these recommendations, the DOCAL task group of the ICRP developed computational phantoms representing the reference adult male and female and then calculated a set of dose conversion coefficients for various types of idealised external exposures. This paper focuses on the dose conversion coefficients for neutrons and investigates their relationship with the conversion coefficients of the protection and operational quantities of ICRP Publication 74. Contributing factors to the differences between these sets of conversion coefficients are discussed in terms of the changes in phantoms employed and the radiation and tissue weighting factors.
© The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Similar articles
-
ICRP Publication 116--the first ICRP/ICRU application of the male and female adult reference computational phantoms.Phys Med Biol. 2014 Sep 21;59(18):5209-24. doi: 10.1088/0031-9155/59/18/5209. Epub 2014 Aug 21. Phys Med Biol. 2014. PMID: 25144220
-
Effective quality factors for neutrons based on the revised ICRP/ICRU recommendations.Radiat Prot Dosimetry. 2005;115(1-4):536-41. doi: 10.1093/rpd/nci004. Radiat Prot Dosimetry. 2005. PMID: 16381781
-
Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms.Phys Med Biol. 2009 Apr 7;54(7):1997-2014. doi: 10.1088/0031-9155/54/7/009. Epub 2009 Mar 5. Phys Med Biol. 2009. PMID: 19265210
-
Overview of ICRP Committee 2 'Doses from Radiation Exposure'.Ann ICRP. 2015 Jun;44(1 Suppl):15-23. doi: 10.1177/0146645314559350. Epub 2015 Feb 12. Ann ICRP. 2015. PMID: 25816256 Review.
-
The impact of ICRP publication 92 on the conversion coefficients in use for cosmic ray dosimetry.Radiat Prot Dosimetry. 2004;109(4):303-9. doi: 10.1093/rpd/nch306. Radiat Prot Dosimetry. 2004. PMID: 15273348 Review.
Cited by
-
Evaluation of radiation exposure dose at double-balloon endoscopy for the patients with small bowel disease.Nagoya J Med Sci. 2016 Aug;78(3):245-53. Nagoya J Med Sci. 2016. PMID: 27578908 Free PMC article.
-
The utilization of guidewires for adjusting the intraoperative catheter malposition during the venous access port implantation: A retrospective study.Medicine (Baltimore). 2024 Nov 8;103(45):e40461. doi: 10.1097/MD.0000000000040461. Medicine (Baltimore). 2024. PMID: 39533627 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources