Liver elastography - an update
- PMID: 24286095
- DOI: 10.11152/mu.2013.2066.154.isp23
Liver elastography - an update
Abstract
Liver fibrosis evaluation is very important for treatment and prognosis in patients with chronic liver disease. The "gold-standard" method for liver fibrosis assessment is still considered to be the liver biopsy, but in the last years non-invasive methods have increasingly been used, especially ultrasound based elastographic ones. The oldest and the only validated elastographic method for non-invasive liver fibrosis evaluation is Transient Elastography (TE). In the last 2-3 years, similar results to TE for liver fibrosis assessment were obtained by using Acoustic Radiation Force Impulse (ARFI) Elastography. More recently, Real Time Shear Wave Elastography (SWE) was developed and promising results were obtained by this technique. Strain elastography is less used in clinical practice for non-invasive liver fibrosis assessment. TE is also useful for predicting liver cirrhosis complications, especially portal hypertension. ARFI elastography seems to be inferior to TE in this field.
Similar articles
-
Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.Ultraschall Med. 2016 Feb;37(1):1-5. doi: 10.1055/s-0035-1567037. Epub 2016 Feb 12. Ultraschall Med. 2016. PMID: 26871407
-
Ultrasound-based elastography for the diagnosis of portal hypertension in cirrhotics.World J Gastroenterol. 2015 Nov 7;21(41):11542-51. doi: 10.3748/wjg.v21.i41.11542. World J Gastroenterol. 2015. PMID: 26556985 Free PMC article. Review.
-
Assessment of liver fibrosis with 2-D shear wave elastography in comparison to transient elastography and acoustic radiation force impulse imaging in patients with chronic liver disease.Ultrasound Med Biol. 2015 Sep;41(9):2350-9. doi: 10.1016/j.ultrasmedbio.2015.04.014. Epub 2015 Jun 24. Ultrasound Med Biol. 2015. PMID: 26116161
-
Ultrasound elastography in liver.Diagn Interv Imaging. 2013 May;94(5):515-34. doi: 10.1016/j.diii.2013.02.005. Epub 2013 Apr 24. Diagn Interv Imaging. 2013. PMID: 23623211 Review.
-
Acoustic radiation force impulse and supersonic shear imaging versus transient elastography for liver fibrosis assessment.Ultrasound Med Biol. 2013 Nov;39(11):1933-41. doi: 10.1016/j.ultrasmedbio.2013.05.003. Epub 2013 Aug 9. Ultrasound Med Biol. 2013. PMID: 23932281
Cited by
-
Noninvasive Assessment of Liver Fibrosis: Current and Future Clinical and Molecular Perspectives.Int J Mol Sci. 2020 Jul 11;21(14):4906. doi: 10.3390/ijms21144906. Int J Mol Sci. 2020. PMID: 32664553 Free PMC article. Review.
-
Serum hyaluronic acid predicts protein-energy malnutrition in chronic hepatitis C.Medicine (Baltimore). 2016 Jun;95(24):e3920. doi: 10.1097/MD.0000000000003920. Medicine (Baltimore). 2016. PMID: 27311000 Free PMC article.
-
Acoustic radiation force impulse (ARFI) elastography in a cohort of alpha-1 antitrypsin-deficient individuals and healthy volunteers.Acta Radiol Open. 2018 Apr 19;7(4):2058460118768363. doi: 10.1177/2058460118768363. eCollection 2018 Apr. Acta Radiol Open. 2018. PMID: 29770228 Free PMC article.
-
Diagnostic accuracy of real-time tissue elastography for the staging of liver fibrosis: a meta-analysis.Eur Radiol. 2015 Jan;25(1):230-8. doi: 10.1007/s00330-014-3364-x. Epub 2014 Aug 23. Eur Radiol. 2015. PMID: 25149296 Review.
-
Fibroscan improves the diagnosis sensitivity of liver fibrosis in patients with chronic hepatitis B.Exp Ther Med. 2016 May;11(5):1673-1677. doi: 10.3892/etm.2016.3135. Epub 2016 Mar 9. Exp Ther Med. 2016. PMID: 27168788 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical