Influence of the washing program on the blood processing performance of a continuous autotransfusion device
- PMID: 24292854
- DOI: 10.1007/s10047-013-0745-x
Influence of the washing program on the blood processing performance of a continuous autotransfusion device
Abstract
The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.
Similar articles
-
Performance of a new-generation continuous autotransfusion device including fat removal and consequences for quality controls.Transfus Med. 2017 Aug;27(4):292-299. doi: 10.1111/tme.12421. Epub 2017 May 19. Transfus Med. 2017. PMID: 28524547
-
Fat elimination during intraoperative autotransfusion: an in vitro investigation.Anesth Analg. 1997 Nov;85(5):959-62. doi: 10.1097/00000539-199711000-00002. Anesth Analg. 1997. PMID: 9356084
-
Fat removal during cell salvage: an optimized program for a discontinuous autotransfusion device.Transfusion. 2016 Jan;56(1):153-9. doi: 10.1111/trf.13286. Epub 2015 Aug 30. Transfusion. 2016. PMID: 26331951
-
Continuous and discontinuous cell-washing autotransfusion systems.J Cardiothorac Vasc Anesth. 2004 Apr;18(2):210-7. doi: 10.1053/j.jvca.2004.01.001. J Cardiothorac Vasc Anesth. 2004. PMID: 15073716 Review. No abstract available.
-
Autotransfusion and blood conservation in urologic oncology.Semin Surg Oncol. 1989;5(4):286-92. doi: 10.1002/ssu.2980050412. Semin Surg Oncol. 1989. PMID: 2672235 Review.
Cited by
-
Tangential flow filtration facilitated washing of human red blood cells: A proof-of-concept study.Vox Sang. 2022 Jun;117(6):803-811. doi: 10.1111/vox.13259. Epub 2022 Mar 9. Vox Sang. 2022. PMID: 35262216 Free PMC article.
-
Traditional and emerging technologies for washing and volume reducing blood products.J Blood Med. 2019 Jan 3;10:37-46. doi: 10.2147/JBM.S166316. eCollection 2019. J Blood Med. 2019. PMID: 30655711 Free PMC article. Review.
-
A novel autotransfusion device saving erythrocytes and platelets used in a 72 h survival swine model of surgically induced controlled blood loss.PLoS One. 2022 Mar 24;17(3):e0260855. doi: 10.1371/journal.pone.0260855. eCollection 2022. PLoS One. 2022. PMID: 35324911 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources