Comparing the reliability of voluntary and evoked muscle actions
- PMID: 24299239
- DOI: 10.1111/cpf.12113
Comparing the reliability of voluntary and evoked muscle actions
Abstract
Purpose: The purpose of this exploratory study was to quantify the test-retest reliability, intertrial variability and correlations between variables calculated during voluntary and evoked muscle actions.
Methods: During three separate trials of isometric leg extension muscle actions with 14 men [mean age (± SD) = 21.9 (± 3.2) years; height = 179.2 (± 8.0) cm; mass = 77.7 (± 10.9) kg], peak torque (PT(V)), time to peak torque (TPT(V)), rate of torque development (RTD(V)), time to peak rate of torque development (TRTD(V)), electromechanical delay (EMD(V)) and EMG amplitude (EMG(RMS)) were quantified for voluntary muscle actions. Peak twitch torque (PTE ), time to peak twitch torque (TPT(E)), rate of torque development (RTD(E)), time to peak rate of torque development (TRTD(E)), electromechanical delay (EMD(E)), peak-to-peak M-wave (Mp-p) and M-wave area (M(area)) were calculated for evoked twitches. All electromyographic measurements were recorded over the vastus lateralis.
Results: Voluntary intraclass correlation coefficients (ICC) were 0.84-0.96, except for TRTD(V) (0.30) and EMD(V) (0.74). Evoked ICC were 0.80-0.95, except for EMD(E) (0.52). Relative standard errors of measurement for TPT and TRT(D) were greater for voluntary than evoked, whereas the value for PTE was greater than PT(V). There were low to moderate correlations (r = -0.41-0.51) between common voluntary and evoked variables.
Conclusions: Evoked variables showed lower intertrial variability than voluntary. Overall, voluntary and evoked muscle actions provide unique, complimentary information regarding neuromuscular function that cannot be used interchangeably.
Keywords: electrical stimulation; isometric muscle actions; minimum difference; neuromuscular testing; test-retest reliability; variability.
© 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Similar articles
-
Age-related differences in rates of torque development and rise in EMG are eliminated by normalization.Exp Gerontol. 2014 Sep;57:18-28. doi: 10.1016/j.exger.2014.04.015. Epub 2014 May 5. Exp Gerontol. 2014. PMID: 24806786
-
Measurement of voluntary activation of the back muscles using transcranial magnetic stimulation.Clin Neurophysiol. 2008 Dec;119(12):2839-45. doi: 10.1016/j.clinph.2008.09.013. Epub 2008 Oct 30. Clin Neurophysiol. 2008. PMID: 18976953
-
Mechanomyographic and electromyographic responses to stimulated and voluntary contractions in the dorsiflexors of young and old men.Muscle Nerve. 2007 Mar;35(3):371-8. doi: 10.1002/mus.20704. Muscle Nerve. 2007. PMID: 17143886
-
Assessment of the reliability of central and peripheral fatigue after sustained maximal voluntary contraction of the quadriceps muscle.Muscle Nerve. 2007 Apr;35(4):486-95. doi: 10.1002/mus.20714. Muscle Nerve. 2007. PMID: 17221875
-
Voluntary performance.Medicina (Kaunas). 2010;46(9):581-94. Medicina (Kaunas). 2010. PMID: 21252592 Review.
Cited by
-
Four weeks of high- versus low-load resistance training to failure on the rate of torque development, electromechanical delay, and contractile twitch properties.J Musculoskelet Neuronal Interact. 2016 Jun 1;16(2):135-44. J Musculoskelet Neuronal Interact. 2016. PMID: 27282457 Free PMC article. Clinical Trial.
-
Metabolic and microvascular function assessed using near-infrared spectroscopy with vascular occlusion in women: age differences and reliability.Exp Physiol. 2023 Jan;108(1):123-134. doi: 10.1113/EP090540. Epub 2022 Nov 24. Exp Physiol. 2023. PMID: 36420592 Free PMC article.
-
Single-session measures of quadriceps neuromuscular function are reliable in healthy females and unaffected by age.Eur J Appl Physiol. 2024 Jun;124(6):1719-1732. doi: 10.1007/s00421-023-05395-x. Epub 2024 Jan 8. Eur J Appl Physiol. 2024. PMID: 38189826 Free PMC article.
-
Postactivation Potentiation of the Plantar Flexors Does Not Directly Translate to Jump Performance in Female Elite Young Soccer Players.Front Physiol. 2018 Mar 23;9:276. doi: 10.3389/fphys.2018.00276. eCollection 2018. Front Physiol. 2018. PMID: 29628898 Free PMC article.
-
The effect of muscle warm-up on voluntary and evoked force-time parameters: A systematic review and meta-analysis with meta-regression.J Sport Health Sci. 2025 Jan 25;14:101024. doi: 10.1016/j.jshs.2025.101024. Online ahead of print. J Sport Health Sci. 2025. PMID: 39864808 Free PMC article. Review.