Regional variation in arterial saturation and oxygen delivery during venoarterial extracorporeal membrane oxygenation
- PMID: 24303601
- PMCID: PMC4557538
Regional variation in arterial saturation and oxygen delivery during venoarterial extracorporeal membrane oxygenation
Abstract
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) can be lifesaving in patients with cardiopulmonary collapse. However, observation studies have implied that oxygenated blood does not pass in a retrograde fashion from the VA-ECMO circuit to the aortic root and arch when the femoral artery (FA) is used. This study aims at accurately measuring the oxygen saturation in various arteries during VA-ECMO through different cannula sites. A total of 20 patients with VA-ECMO were in the study. Fourteen patients had FA cannulation, two patients received axillary arterial (AA) cannulation, and four patients received cannulation of the ascending aorta. Oxygen saturation was measured simultaneously in the radial artery and oxygenator outlet. In the patient group with FA cannulation, the oxygen saturation was lower in the radial artery (97%) when compared with the oxygenator outlet (> 99%). In the subset group of patients with severe lung dysfunction, oxygen saturation was even lower in the radial artery (73% saturation). In the patient group with AA cannulation, the oxygen saturation and partial oxygen pressure (PO2) in the oxygenator outlet and radial artery were similar (99% or greater). In the patient group with direct ascending aorta cannulation, the oxygen saturation and PO2 in the oxygenator outlet and radial artery were similar as well. Regional variations occur in the blood oxygen saturation depending on the site of the arterial cannulation in patients with VA-ECMO. With FA cannulation, the oxygen saturation in the radial artery is significantly lower than the one in the oxygenator outlet. This may imply that the coronaries and the brain receive hypoxic blood from the left ventricle. These results suggest that antegrade cannulation for VA-ECMO improves oxygen delivery to the proximal aorta distribution.
Keywords: VA-ECMO, arterial oxygen saturation.
Conflict of interest statement
The senior author has stated that the authors have reported no material, financial, or other relationship with any healthcare-related business or other entity whose products or services are discussed in this paper.
References
-
- Seo T, Ito T, Iio K, Kato J, Takagi H.. Experimental study on the hemodynamic effects of veno-arterial extracorporeal membrane oxygenation with an automatically driven blood pump on puppies. Artif Organs. 1991;15:402–407. - PubMed
-
- Kato J, Seo T, Ando H, Takagi H, Ito T.. Coronary arterial perfusion during venoarterial extracorporeal oxygenation. J Thorac Cardiovasc Surg. 1996;111:630–636. - PubMed
-
- Kamimura T, Sakamoto H, Misumi K.. Regional blood flow distribution from the proximal arterial cannula during veno-arterial extracorporeal membrane oxygenation in neonatal dog. J Vet Med Sci. 1999;61:311–315. - PubMed
-
- Wada H, Watari M, Sueda T, et al. Cerebral tissue oxygen saturation during percutaneous cardiopulmonary support in a canine model of respiratory failure. Artif Organs. 2000;24:640–643. - PubMed
-
- Nakamura T, Takata M, Arai M, Nakagawa S, Miyasaka K.. The effect of left-to-right shunting on coronary oxygenation during extracorporeal membrane oxygenation. J Pediatr Surg. 1999;32:981–985. - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources