Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Dec;22(9):750-6.
doi: 10.1097/IJG.0b013e318264ba4d.

Ahmed valve, suture-less implantation: A new approach to an easier technique

Affiliations

Ahmed valve, suture-less implantation: A new approach to an easier technique

Salvador García-Delpech et al. J Glaucoma. 2013 Dec.

Abstract

Purpose: Tissue adhesives have been used in ophthalmology instead of sutures to minimize the operating time. This case series investigated the effectiveness and safety of use of cyanoacrylate in Ahmed valve implantation through pars plana for refractory glaucoma.

Patients and methods: Seventeen eyes of 17 patients with refractory glaucoma underwent Ahmed valve scleral suture-less implantation through pars plana with a cyanoacrylate suture of the plate. Refractory glaucoma was defined as intraocular pressure (IOP) ≥ 21 mm Hg with antiglaucoma eye drops, good adherence to treatment, and no previous glaucoma surgery. IOP control and development of complications were evaluated during the follow-up (mean follow-up, 13.23 mo, 6 to 28 mo).

Results: IOP control, defined as IOP ≤ 21 mm Hg with or without antiglaucoma eye drops, was achieved in 82.2% of patients, and 58.8% were able to eliminate antiglaucoma eye drops. Mean surgical time was 9.76 ± 2.60 and 6 ± 0.81 minutes in patients with previous vitrectomy (4 cases). Postoperative complications included transiently increased IOP, transient hyphema, early postoperative hypotony (4 cases), and tube block by the vitreous (2 cases): 1 resolved by Nd:YAG and the other by second vitrectomy. No cases of tube or plate extrusion, plate migration, choroidal or retinal detachment, or vitreous hemorrhage were observed.

Conclusions: These results are promising and demonstrate a safe and effective alternative to the traditional scleral suture. Our data suggest that Ahmed valve implantation through pars plana with cyanoacrylate is a safe and effective method for refractory glaucoma. Further studies are needed to confirm our observation.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources