Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jun;45(6):1060-5.
doi: 10.1093/ejcts/ezt537. Epub 2013 Dec 3.

Preoperative assessment of the aortic arch in children younger than 1 year with congenital heart disease: utility of low-dose high-pitch dual-source computed tomography. A single-centre, retrospective analysis of 62 cases

Affiliations

Preoperative assessment of the aortic arch in children younger than 1 year with congenital heart disease: utility of low-dose high-pitch dual-source computed tomography. A single-centre, retrospective analysis of 62 cases

Martin Glöckler et al. Eur J Cardiothorac Surg. 2014 Jun.

Abstract

Objectives: To evaluate the feasibility, image quality and impact of 3D imaging in low-dose high-pitch dual-source computed tomography (DSCT) to assess arbitrary anatomical malformations of the aortic arch in children <1 year of age with congenital heart disease (CHD).

Methods: Between January 2010 and May 2013, DSCT was performed to assess the aortic arch anatomy in a total of 62 consecutive patients with CHD (aged 0-348 days). DSCT was used whenever conventional echocardiography was not sufficient to display the complex anatomy entirely. Image data acquisition was realized within a single cardiac cycle using prospective ECG triggering. 3D reconstruction for surgical planning was performed. Image quality was assessed retrospectively, using a 4-point scale from '1 = no artefacts' to '4 = uninterpretable'. The accuracy and impact of the 3D reconstructions was compared with intraoperative findings using a 5-point scale (from '1 = essential' to '5 = misleading'). Administered radiation exposure was evaluated.

Results: Imaging was successful in all patients, image quality was rated 1.34 on the 4-point scale and the impact of the 3D reconstructions for surgical planning was 2.05 on the 5-point scale. Mean dose-length product was 6.8 ± 2.6 mGy cm, and the effective dose was 0.45 ± 0.13 mSv (0.21-0.74).

Conclusions: DSCT is a fast and appropriate imaging modality in the preoperative assessment of the aortic arch for surgical planning in CHD.

Keywords: 3D imaging; Complex vascular anatomy; Computed tomography; Low radiation; Newborn.

PubMed Disclaimer