SERS-based competitive immunoassay of troponin I and CK-MB markers for early diagnosis of acute myocardial infarction
- PMID: 24310060
- DOI: 10.1039/c3cc47850e
SERS-based competitive immunoassay of troponin I and CK-MB markers for early diagnosis of acute myocardial infarction
Abstract
We report a SERS-based competitive immunoassay technique for the early diagnosis of acute myocardial infarction (AMI). Simultaneous quantification of the dual cardiac markers, CK-MB and troponin I, was achieved by single wavelength excitation.
Similar articles
-
SERS-based immunoassay using gold-patterned array chips for rapid and sensitive detection of dual cardiac biomarkers.Analyst. 2019 Nov 4;144(22):6533-6540. doi: 10.1039/c9an01260e. Analyst. 2019. PMID: 31553332
-
Troponin T or troponin I or CK-MB (or none?).Eur Heart J. 1998 Nov;19 Suppl N:N16-24. Eur Heart J. 1998. PMID: 9857934
-
[Quantitative analysis of serum troponin I and myoglobin in patients with acute myocardial infarction].Di Yi Jun Yi Da Xue Xue Bao. 2005 May;25(5):550-1. Di Yi Jun Yi Da Xue Xue Bao. 2005. PMID: 15897132 Chinese.
-
A strategy for the use of cardiac injury markers (troponin I and T, creatine kinase-MB mass and isoforms, and myoglobin) in the diagnosis of acute myocardial infarction.Arch Pathol Lab Med. 1998 Mar;122(3):245-51. Arch Pathol Lab Med. 1998. PMID: 9823862 Review.
-
A tale of two biomarkers: the use of troponin and CK-MB in contemporary practice.Clin Lab Sci. 2010 Summer;23(3):134-40. Clin Lab Sci. 2010. PMID: 20734885 Review. No abstract available.
Cited by
-
Nanoscale Technologies for Prevention and Treatment of Heart Failure: Challenges and Opportunities.Chem Rev. 2019 Nov 13;119(21):11352-11390. doi: 10.1021/acs.chemrev.8b00323. Epub 2019 Sep 6. Chem Rev. 2019. PMID: 31490059 Free PMC article. Review.
-
In vitro evaluation of aspirin-induced HspB1 against heat stress damage in chicken myocardial cells.Cell Stress Chaperones. 2016 May;21(3):405-13. doi: 10.1007/s12192-016-0666-8. Epub 2016 Feb 24. Cell Stress Chaperones. 2016. PMID: 26910344 Free PMC article.
-
Troponin Aptamer on an Atomically Flat Au Nanoplate Platform for Detection of Cardiac Troponin I.Nanomaterials (Basel). 2020 Jul 18;10(7):1402. doi: 10.3390/nano10071402. Nanomaterials (Basel). 2020. PMID: 32708486 Free PMC article.
-
Design and Optimization of A Magneto-Plasmonic Sandwich Biosensor for Integration within Microfluidic Devices.Biosensors (Basel). 2022 Sep 27;12(10):799. doi: 10.3390/bios12100799. Biosensors (Basel). 2022. PMID: 36290935 Free PMC article.
-
2D Material-Based Surface-Enhanced Raman Spectroscopy Platforms (Either Alone or in Nanocomposite Form)-From a Chemical Enhancement Perspective.ACS Omega. 2024 Sep 11;9(38):40242-40258. doi: 10.1021/acsomega.4c06398. eCollection 2024 Sep 24. ACS Omega. 2024. PMID: 39346812 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous