Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jan 1:944:166-74.
doi: 10.1016/j.jchromb.2013.11.017. Epub 2013 Nov 18.

A rapid, sensitive method for quantitative analysis of underivatized amino acids by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Affiliations

A rapid, sensitive method for quantitative analysis of underivatized amino acids by liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Anthony Le et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

The quantitation of free amino acids from physiologic samples is essential for diagnosing and monitoring patients with inherited metabolic disorders. Current methods are hindered by long preparative and/or analysis times, expensive reagents, and often suboptimal performance characteristics. To overcome these challenges, a improved method for amino acid analysis using liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated. Samples were deproteinized with sulfosalicylic acid and supernatants diluted with tridecafluoroheptanoic acid. Chromatographic separation of amino acids occurred using two columns, with conditions favoring resolution of isobaric compounds and minimizing ion suppression. Eluted compounds were detected by selective reaction monitoring, and quantitated by relating peak areas of amino acids to externally run standards. Validation studies evaluated linearity, within- and between-run imprecision, lower limits of detection and quantification for 33 amino acids, and correlation with the Biochrom 30 Amino Acid Analyzer. Total run time including re-equilibration was 15min per sample. Within-run precision averaged 2.8% for all compounds, with an average linear correlation coefficient of 0.995. The majority of compounds were reliably quantitated at ≤0.1μM. Between-run precision averaged 4.0%. Results showed excellent correlation with the Biochrom 30 amino acid analyzer with an average overall correlation of 0.908. We conclude that our method is extremely sensitive, specific and reproducible and represents an improvement over other currently available technologies.

Keywords: Amino acid analysis; LC–MS/MS; PGC; SRM; TDFHA; Tandem mass spectrometry; Underivatized; liquid chromatography tandem mass spectrometry; porous graphitic carbon; selective reaction monitoring; tridecafluoroheptanoic acid.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources