Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 May;211(1):82-96.
doi: 10.1111/apha.12212. Epub 2014 Jan 2.

Fatigue effects on the electromechanical delay components during the relaxation phase after isometric contraction

Affiliations

Fatigue effects on the electromechanical delay components during the relaxation phase after isometric contraction

E Cè et al. Acta Physiol (Oxf). 2014 May.

Abstract

Aim: By a combined electromyographic (EMG), mechanomyographic (MMG) and force (F) analysis, the electromechanical delay during muscle relaxation (R-DelayTOT ) was partitioned into electrochemical and mechanical components. The study aimed to evaluate the effects of fatigue on R-DelayTOT components and to assess their intersession and interday reliability Intraclass correlation coefficient (ICC).

Methods: During tetanic stimulations, EMG, MMG and F were recorded from the human gastrocnemius medialis muscle before and after fatigue. The latency between EMG and MMG ripple cessations (R-Δt EMG-MMGR , electrochemical R-DelayTOT component); between MMG ripple cessation and F decay onset (R-Δt MMGR -F, first R-DelayTOT mechanical component); and between F decay onset and maximum MMG negative peak (R-Δt F-MMGp-p , second R-DelayTOT mechanical component) was calculated.

Results: Before fatigue, R-Δt F-MMGp-p was the major contributor (61.9 ± 1.7 ms, 75%) to R-DelayTOT (82.7 ± 1.0 ms), while R-Δt EMG-MMGR and R-Δt MMGR -F accounted for 16% (13.3 ± 1.2 ms) and 9% (7.5 ± 1.0 ms) respectively. After fatigue, R-DelayTOT , R-Δt EMG-MMGR and R-Δt MMGR -F increased by 11, 41 and 67%, respectively (P < 0.05), whereas R-Δt F-MMGp-p did not change. Consequently, the relative contribution of R-Δt EMG-MMGR , R-Δt MMGR -F and R-Δt F-MMGp-p , to R-DelayTOT changed to 20 ± 2, 12 ± 1 and 68 ± 2% respectively. Measurement reliability was always from high to very high (ICC 0.705-0.959).

Conclusion: Fatigue altered the processes between neuromuscular activation cessation and force decay onset, but not the second mechanical component (cross-bridges detachment rate and series elastic components release). This combined approach provided reliable measurement of the different R-DelayTOT components and it may represent a valid tool to get more insights on muscle electromechanical behaviour.

Keywords: electromyogram; force; latency; mechanomyogram; reliability; skeletal muscle.

PubMed Disclaimer

Publication types

LinkOut - more resources