ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine
- PMID: 24320778
- DOI: 10.1111/vcp.12099
ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine
Abstract
Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting.
Keywords: Allowable total error; bench-top; handheld; in-clinic; near-patient; quality control.
© 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Similar articles
-
ASVCP guidelines: allowable total error guidelines for biochemistry.Vet Clin Pathol. 2013 Dec;42(4):424-36. doi: 10.1111/vcp.12101. Vet Clin Pathol. 2013. PMID: 24320779
-
Survey of point-of-care instrumentation, analysis, and quality assurance in veterinary practice.Vet Clin Pathol. 2014 Jun;43(2):185-92. doi: 10.1111/vcp.12142. Epub 2014 Apr 21. Vet Clin Pathol. 2014. PMID: 24750496
-
Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.J Am Vet Med Assoc. 2013 Jan 15;242(2):182-92. doi: 10.2460/javma.242.2.182. J Am Vet Med Assoc. 2013. PMID: 23276094
-
Quality management recommendations for automated and manual in-house hematology of domestic animals.Vet Clin North Am Small Anim Pract. 2012 Jan;42(1):11-22. doi: 10.1016/j.cvsm.2011.09.004. Vet Clin North Am Small Anim Pract. 2012. PMID: 22285154 Review.
-
The elephant in the room (and how to lead it out): In-clinic laboratory quality challenges.J Am Anim Hosp Assoc. 2014 Nov-Dec;50(6):375-82. doi: 10.5326/JAAHA-MS-6231. Epub 2014 Sep 23. J Am Anim Hosp Assoc. 2014. PMID: 25251431 Review.
Cited by
-
Effect of up to 30-days of storage at different temperatures on detection of feline kidney injury molecule-1 in urine.BMC Vet Res. 2022 Nov 4;18(1):389. doi: 10.1186/s12917-022-03489-w. BMC Vet Res. 2022. PMID: 36333744 Free PMC article.
-
Haematology and plasma biochemistry reference intervals of Galapagos tortoises from Isabela Island.Conserv Physiol. 2025 Jul 29;13(1):coaf054. doi: 10.1093/conphys/coaf054. eCollection 2025. Conserv Physiol. 2025. PMID: 40735306 Free PMC article.
-
Clinical utility of currently available biomarkers in inflammatory enteropathies of dogs.J Vet Intern Med. 2018 Sep;32(5):1495-1508. doi: 10.1111/jvim.15247. Epub 2018 Sep 17. J Vet Intern Med. 2018. PMID: 30222209 Free PMC article. Review.
-
Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives.Sensors (Basel). 2021 Jul 30;21(15):5185. doi: 10.3390/s21155185. Sensors (Basel). 2021. PMID: 34372422 Free PMC article. Review.
-
Practical application of Six Sigma management in analytical biochemistry processes in clinical settings.J Clin Lab Anal. 2020 Jan;34(1):e23126. doi: 10.1002/jcla.23126. Epub 2019 Nov 27. J Clin Lab Anal. 2020. PMID: 31774217 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources