Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1987 Jan;25(1):97-9.
doi: 10.1128/jcm.25.1.97-99.1987.

Micromethod for assaying reverse transcriptase of human T-cell lymphotropic virus type III/lymphadenopathy-associated virus

Comparative Study

Micromethod for assaying reverse transcriptase of human T-cell lymphotropic virus type III/lymphadenopathy-associated virus

T J Spira et al. J Clin Microbiol. 1987 Jan.

Abstract

A micromethod for assaying the reverse transcriptase enzyme of human T-cell lymphotropic virus type III/lymphadenopathy-associated virus in cocultures of clinical specimens for viral isolation was developed and compared with the macromethod in use. Ultracentrifuged, pelleted, and solubilized viral culture supernatants were transferred into either tubes (macromethod) or microtiter plates (micromethod) and incubated with tritiated enzyme substrate. Trichloroacetic acid-precipitated DNA was collected on individual filter papers with a Millipore filtration manifold (macromethod) or on filter sheets using a semiautomated cell harvester (micromethod). Filters were then placed in scintillation fluid and counted on a beta scintillation counter. Results of the micromethod significantly correlated to those of the macromethod, with a linear relationship between the two. The cutoffs for positivity based on the mean + 2 standard deviations for a set of known negative specimens (n = 19) was 4,973 cpm for the micromethod compared with 5,336 for the macromethod. The intrarun and interrun variations were comparable for both methods. There was a 67% increase in the maximal daily number of specimens which could be run (100 versus 60) as well as a reduction in reagent use. In summary, the micromethod utilizing a semiautomated cell harvester is comparable to the existing macromethod in accuracy and is an improvement due to savings in time and reagents.

PubMed Disclaimer

References

    1. Proc Natl Acad Sci U S A. 1971 Jul;68(7):1507-11 - PubMed
    1. Proc Natl Acad Sci U S A. 1971 Sep;68(9):2203-6 - PubMed
    1. Science. 1972 May 19;176(4036):798-800 - PubMed

Publication types

Substances

LinkOut - more resources