Interatrial conduction during cardiac pacing
- PMID: 2432504
- DOI: 10.1111/j.1540-8159.1986.tb06665.x
Interatrial conduction during cardiac pacing
Abstract
DDD pacemakers sense and pace right-sided cardiac chambers. The relationship of atrial to ventricular systole on the left side of the heart is of importance for systemic hemodynamics. Effective atrioventricular synchrony is partially determined by interatrial conduction time (IACT). At the time of DDD pacemaker implantation, interatrial conduction was measured using an intraesophageal pill electrode in 25 patients who were on no cardiac medications. Mean interatrial conduction time for all patients prolonged from 95 +/- 18 ms during sinus rhythm to 122 +/- 30 ms during right atrial pacing (p less than 0.001). In 16 patients with P wave duration less than 110 ms interatrial conduction prolonged from 85 +/- 10 ms during sinus rhythm to 111 +/- 9 ms during right atrial pacing (p less than 0.01) compared to 114 +/- 20 ms prolonging to 111 +/- 19 ms (p less than 0.01) in 9 patients with P wave duration greater than 110 ms. In each patient, while atrioventricular conduction prolonged with incremental right atrial pacing, interatrial conduction times did not vary. Interatrial conduction prolongs from baseline during atrial pacing and remains constant at all paced rates from 60-160 beats per minute. In addition to longer interatrial conduction times during sinus rhythm, patients with electrocardiographic P wave prolongation have longer interatrial conduction times during right atrial pacing than do normals (p less than 0.001). Based on interatrial conduction times alone, the AV interval during DDD cardiac pacing should be approximately 25 ms longer during AV pacing as compared to atrial tracking.
Similar articles
-
The importance of the left atrioventricular interval during atrioventricular sequential pacing.Pacing Clin Electrophysiol. 1997 Dec;20(12 Pt 1):2958-66. doi: 10.1111/j.1540-8159.1997.tb05467.x. Pacing Clin Electrophysiol. 1997. PMID: 9455758
-
Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.Adv Clin Exp Med. 2016 Sep-Oct;25(5):845-850. doi: 10.17219/acem/63351. Adv Clin Exp Med. 2016. PMID: 28028946
-
Nonphysiological left heart AV intervals as a result of DDD and AAI "physiological" pacing.Pacing Clin Electrophysiol. 1991 Nov;14(11 Pt 2):1752-6. doi: 10.1111/j.1540-8159.1991.tb02760.x. Pacing Clin Electrophysiol. 1991. PMID: 1721169
-
DDD pacing and interatrial conduction block: importance of optimal AV interval setting.Pacing Clin Electrophysiol. 2000 Sep;23(9):1448-50. doi: 10.1111/j.1540-8159.2000.tb00981.x. Pacing Clin Electrophysiol. 2000. PMID: 11025908 Review.
-
Atrial pacing for sick sinus syndrome.Clin Cardiol. 1990 Jan;13(1):43-7. doi: 10.1002/clc.4960130108. Clin Cardiol. 1990. PMID: 2404646 Review.
Cited by
-
Echocardiographic AV-interval optimization in patients with reduced left ventricular function.Cardiovasc Ultrasound. 2004 Dec 17;2:30. doi: 10.1186/1476-7120-2-30. Cardiovasc Ultrasound. 2004. PMID: 15606916 Free PMC article. Clinical Trial.
-
R-wave synchronised atrial pacing in pediatric patients with postoperative junctional ectopic tachycardia: the atrioventricular interval investigated by computational analysis and clinical evaluation.Biomed Eng Online. 2017 Dec 19;16(1):139. doi: 10.1186/s12938-017-0430-z. Biomed Eng Online. 2017. PMID: 29258517 Free PMC article.
-
The search for optimal atrioventricular interval.J Interv Card Electrophysiol. 2005 Nov;14(2):95-8. doi: 10.1007/s10840-005-4514-5. J Interv Card Electrophysiol. 2005. PMID: 16374556 No abstract available.
-
Effect of atrioventricular conduction prolongation on optimization of paced atrioventricular delay for biventricular pacing after cardiac surgery.J Cardiothorac Vasc Anesth. 2012 Apr;26(2):209-16. doi: 10.1053/j.jvca.2011.07.030. Epub 2011 Oct 14. J Cardiothorac Vasc Anesth. 2012. PMID: 22000982 Free PMC article. Clinical Trial.
-
Utilization of Electrocardiographic P-wave Duration for AV Interval Optimization in Dual-Chamber Pacemakers.Indian Pacing Electrophysiol J. 2010 Sep 5;10(9):383-92. Indian Pacing Electrophysiol J. 2010. PMID: 20930956 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials