Pilot evaluation of an integrated monitor-adhesive patch for long-term cardiac arrhythmia detection in India
- PMID: 24325206
- DOI: 10.1586/14779072.2013.867807
Pilot evaluation of an integrated monitor-adhesive patch for long-term cardiac arrhythmia detection in India
Abstract
Electrocardiographic monitoring represents one of the most reliable and time-tested methods for reducing ambiguity in cardiac arrhythmia diagnosis. In India, the resting ECG is generally the first tool of choice for in-clinic diagnosis. The external loop recorder (ELR) is another useful tool that compounds the advantages of traditional tools by coupling ambulatory monitoring with a long-term window. Thus, the objective was to test the use of a 7-day ELR for arrhythmia diagnosis in India for a broad range of presenting symptoms. In this study set in the Indian healthcare environment, an auto-triggered, wireless patch-type ELR was used with 125 patients (62.5 ± 16.7 years, 76 males) presenting a broad range of symptoms. Eighty percent of the symptoms were related to syncope, presyncope or palpitations. Patients were administered an ELR for 7-28 days depending on the physician's prescription. Prespecified significant arrhythmias included sinus pause >2 s, symptomatic bradycardia <40 b.p.m., second-degree (and higher) AV block, complete heart block, ventricular fibrillation, sustained/nonsustained ventricular tachycardia (>3 beats), atrial fibrillation (chronic or paroxysmal), atrial flutter and supraventricular tachycardia (SVT) >130 b.p.m. Diagnostic yield was 38% when a stringent tabulation methodology considering only clinically significant arrhythmia was used. When first-degree AV block, premature atrial and ventricular beats, couplets (both atrial and ventricular in origin), bigeminy or trigeminy, or sudden changes in rate (noted as sinus arrhythmia) were included in the calculation, diagnostic yield was 80%. Patient compliance was 98%; patients wore the patch for the entire prescribed monitoring period without disruption. Seventy percent of the reported symptoms corresponded with an arrhythmia. Use of the ELR led to therapy change in 24% of patients: 15 patients went on to receive an implantable cardioverter defibrillator or pacemaker, 4 received ablation therapy and 11 altered their medication after diagnosis. This study demonstrates that a high diagnostic yield for clinically significant arrhythmias and high patient compliance can be achieved with a wearable patch monitor in Indian patients suffering from a variety of symptoms.
Similar articles
-
Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations.Europace. 2014 Jun;16(6):914-22. doi: 10.1093/europace/eut337. Epub 2013 Oct 24. Europace. 2014. PMID: 24158255
-
The utility of implantable loop recorders for diagnosing unexplained syncope in 100 consecutive patients: five-year, single-center experience.J Invasive Cardiol. 2006 Jul;18(7):313-5. J Invasive Cardiol. 2006. PMID: 16816436
-
Detection of asymptomatic arrhythmias in unexplained syncope.Am Heart J. 2004 Aug;148(2):326-32. doi: 10.1016/j.ahj.2004.01.024. Am Heart J. 2004. PMID: 15309004
-
Risk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator.Eur Heart J. 2013 Aug;34(29):2230-42. doi: 10.1093/eurheartj/eht167. Epub 2013 May 31. Eur Heart J. 2013. PMID: 23729691 Review.
-
[Dangerous arrhythmias].Schweiz Med Wochenschr. 1993 May 1;123(17):833-43. Schweiz Med Wochenschr. 1993. PMID: 8497770 Review. German.
Cited by
-
Identifying high risk patients post myocardial infarction with reduced left ventricular function using loop recorders INSPIRE-ELR clinical study.Indian Heart J. 2022 May-Jun;74(3):194-200. doi: 10.1016/j.ihj.2022.04.010. Epub 2022 Apr 29. Indian Heart J. 2022. PMID: 35490849 Free PMC article.
-
Advancing cardiac arrhythmia management: The integration of wearable technology and remote monitoring.World J Cardiol. 2025 Jul 26;17(7):106841. doi: 10.4330/wjc.v17.i7.106841. World J Cardiol. 2025. PMID: 40741014 Free PMC article. Review.
-
Accuracy of mHealth Devices for Atrial Fibrillation Screening: Systematic Review.JMIR Mhealth Uhealth. 2019 Jun 16;7(6):e13641. doi: 10.2196/13641. JMIR Mhealth Uhealth. 2019. PMID: 31199337 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical