Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Mar;39(2):135-41.
doi: 10.1111/ced.12254. Epub 2013 Dec 16.

Assessment of nailfold capillaroscopy in systemic sclerosis by different optical magnification methods

Affiliations

Assessment of nailfold capillaroscopy in systemic sclerosis by different optical magnification methods

N G Mazzotti et al. Clin Exp Dermatol. 2014 Mar.

Abstract

Background: Systemic sclerosis (SSc) is characterized by target-organ fibrosis and microvascular dysfunction, which can be assessed using nailfold capillaroscopy. Dermoscopy is a useful and easily performed method for diagnosing skin lesions.

Aim: To compare conventional capillaroscopy, using the gold-standard method (conventional stereomicroscope nailfold capillaroscopy; SNFC), with polarized light noncontact dermoscopy (PNCD) and nonpolarized light contact dermoscopy (NPCD), and to evaluate their accuracy in diagnosing characteristic SSc-related alterations.

Methods: The study enrolled 45 patients with SSc. Capillaroscopy images and photographs were taken with three devices, SNFC, NPCD and PNCD, and these images were randomly analysed by a blinded observer.

Results: The scleroderma pattern was found in 83% of patients. PNCD and NPCD were highly sensitive in identifying the presence of focal capillary loss (96.4% and 100%, respectively), haemorrhage (96.2% and 92%, respectively), and scleroderma (91.9%, 94.6%), and showed high specificity for haemorrhage and enlarged loops. The intra-observer kappa values for detection of the scleroderma pattern by SNFC images, NPCD and PNCD were moderate to good: (κ = 0.71 (95% CI 0.44-0.95), κ = 0.60 (95% CI 0.35-0.83) and κ = 0.60 (95% CI 0.32-0.86), respectively. Evaluation of haemorrhage presence gave high kappa values for all methods: κ = 0.77 (95% CI 0.57-0.95), κ = 0.90 (95% CI 0.76-1.00) and κ = 0.95 (95% CI 0.85-1.00), respectively.

Conclusions: Both polarized and nonpolarized dermoscopy are reliable methods for valuation of nailfold capillaroscopy in patients with SSc. They are easy to perform, with good rates of accuracy and results that are comparable with traditional capillaroscopy.

PubMed Disclaimer

Publication types