The effects of pneumatic tube transport on fresh and stored platelets in additive solution
- PMID: 24333086
- PMCID: PMC3926735
- DOI: 10.2450/2013.0097-13
The effects of pneumatic tube transport on fresh and stored platelets in additive solution
Abstract
Background: Limited scientific work has been conducted on potential in vitro effects of transport on pneumatic tube systems on blood components, in particular platelets.
Materials and methods: To evaluate the possible effects of the Swisslog TranspoNet system on the cellular, metabolic, phenotypic and secreting properties of fresh and stored platelets, we set up a four-arm paired study comparing transported and non-transported platelets. Platelets were aliquoted, prepared with the OrbiSac system and suspended in 70% SSP+ (n=8). All in vitro parameters were monitored over a 7-day storage period.
Results: Throughout storage, no differences were observed in glucose consumption, lactate production, pH, pCO2, ATP, hypotonic shock response reactivity, CD62P, PAC-1, platelet endothelial cell adhesion molecule-1 or CD42b. The release of sCD40L increased (p<0.01) in all units but without any significant differences between groups.
Conclusion: The storage stability of all platelets conveyed by the Swisslog TranspoNet system was not impaired throughout 7 days of storage. The Swisslog TranspoNet system does not, therefore, seem to be a risk for increased metabolic activity, activation or release reactions from the platelets. This lack of effect of the pneumatic tube transport system did not seem to be affected by the age of the platelets or repeated transport.
Similar articles
-
Storage of buffy-coat-derived platelets in additive solution: in vitro effects on platelets of the air bubbles and foam included in the final unit.Blood Transfus. 2011 Apr;9(2):182-8. doi: 10.2450/2010.0045-10. Epub 2010 Oct 25. Blood Transfus. 2011. PMID: 21084001 Free PMC article.
-
Automated preparation of whole blood-derived platelets suspended in two different platelet additive solutions and stored for 7 days.Transfusion. 2014 Feb;54(2):426-33. doi: 10.1111/trf.12283. Epub 2013 May 30. Transfusion. 2014. PMID: 23721299
-
Glucose in platelet additive solutions: to add or not to add?Transfus Apher Sci. 2011 Jun;44(3):283-95. doi: 10.1016/j.transci.2011.03.003. Epub 2011 Apr 14. Transfus Apher Sci. 2011. PMID: 21493158 Review.
-
In vitro and in vivo effects of potassium and magnesium on storage up to 7 days of apheresis platelet concentrates in platelet additive solution.Vox Sang. 2008 Feb;94(2):96-102. doi: 10.1111/j.1423-0410.2007.01002.x. Epub 2007 Nov 22. Vox Sang. 2008. PMID: 18034788 Clinical Trial.
-
Additive solutions for the storage of platelets for transfusion.Transfus Med. 2000 Dec;10(4):257-64. doi: 10.1046/j.1365-3148.2000.00262.x. Transfus Med. 2000. PMID: 11123809 Review. No abstract available.
Cited by
-
Effect of Pneumatic Tubing System Transport on Platelet Apheresis Units.Cardiovasc Eng Technol. 2018 Sep;9(3):515-527. doi: 10.1007/s13239-018-0361-2. Epub 2018 May 21. Cardiovasc Eng Technol. 2018. PMID: 29785664 Free PMC article.
-
Triple apheresis platelet concentrate quality after pneumatic tube system, conveyor box, and courier transport: An observational study.Health Sci Rep. 2022 Apr 7;5(3):e596. doi: 10.1002/hsr2.596. eCollection 2022 Apr. Health Sci Rep. 2022. PMID: 35425867 Free PMC article.
-
Evaluation of the pneumatic tube system for transportation of packed red cell units.Asian J Transfus Sci. 2015 Jul-Dec;9(2):195-8. doi: 10.4103/0973-6247.154254. Asian J Transfus Sci. 2015. PMID: 26420944 Free PMC article.
References
-
- Amann G, Zehntner C, Marti F, et al. Effect of acceleration forces during transport through a pneumatic tube system on ROTEM(R) analysis. Clin Chem Lab Med. 2012;50:1335–42. - PubMed
-
- Bolliger D, Seeberger MD, Tanaka KA, et al. Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry. Platelets. 2009;20:458–65. - PubMed
-
- Glas M, Mauer D, Kassas H, et al. Sample transport by pneumatic tube system alters results of multiple electrode aggregometry but not rotational thromboelastometry. Platelets. 2012;24:454–61. - PubMed
-
- Poznanski W, Smith F, Bodley F. Implementation of a pneumatic-tube system for transport of blood specimens. Am J Clin Pathol. 1978;70:291–5. - PubMed
-
- Pragay DA, Fan P, Brinkley S, et al. A computer directed pneumatic tube system: its effects on specimens. Clin Biochem. 1980;13:259–61. - PubMed
MeSH terms
Substances
LinkOut - more resources