Single-donor platelet apheresis: observational comparison of the new Haemonetics Universal Platelet protocol with the previous Concentrated Single Donor Platelet protocol
- PMID: 24333087
- PMCID: PMC4039704
- DOI: 10.2450/2013.0119-13
Single-donor platelet apheresis: observational comparison of the new Haemonetics Universal Platelet protocol with the previous Concentrated Single Donor Platelet protocol
Abstract
Background: The Haemonetics MCS(®)+ cell separator is a device dedicated to the collection of leucoreduced single-donor platelets. The new Universal Platelet protocol has been introduced to improve the efficiency of apheresis and increase flexibility in the collection of leucoreduced platelets in combination with red blood cells and plasma. In this study we compared its performance with that of the previous Concentrated Single Donor Platelet protocol.
Materials and methods: This observational study had a within-subject design and involved 135 donors who underwent plateletapheresis with both protocols. The primary end-point was collection efficiency; secondary end-points were other performance indices, such as procedure time and collection rate. A satisfaction questionnaire was also administered to the 135 donors to evaluate opinions on duration, comfort and side-effects of donations with the two protocols. For each parameter of interest, we tested the difference between the two protocols within donors, using a one-sample t-test or exact McNemar's test as appropriate.
Results: The collection efficiency of the Universal Platelet protocol was significantly higher than that of the Concentrated Single Donor Platelet protocol (58% vs 47%; p<0.0001). The Universal Platelet Protocol collected more platelets in less time, leading to a higher collection rate (6.5 vs 5.0×10(9)/min; p<0.0001). In general, donors found apheresis with the Universal Platelet protocol of equal duration or faster, of similar or greater comfort and with an equal number or fewer side effects, compared with the Concentrated Single Donor Platelet protocol.
Discussion: Our study endorses the use of the new Universal Platelet protocol in daily transfusion practice since it substantially improves collection efficiency in leucoreduced platelet procedures compared with the Concentrated Single Donor Platelet protocol. This technical improvement seems to be accompanied by equal or greater comfort for the donor.
Figures


Similar articles
-
Effectiveness of the haemonetics MCS cell separator in the collection of apheresis platelets.Transfus Apher Sci. 2015 Dec;53(3):396-8. doi: 10.1016/j.transci.2015.08.002. Epub 2015 Aug 10. Transfus Apher Sci. 2015. PMID: 26283175 Clinical Trial.
-
[The influence of initial values of donor platelets count on the efficiency of plateletpheresis with the cell separator Fenval Baxter Amicus s.v.2.51].Med Arh. 2009;63(2):67-70. Med Arh. 2009. PMID: 19537658 Bosnian.
-
Comparison of Plateletpheresis on the Haemonetics and Trima Accel Cell Separators.Ther Apher Dial. 2018 Feb;22(1):87-90. doi: 10.1111/1744-9987.12607. Epub 2017 Oct 30. Ther Apher Dial. 2018. PMID: 29082642
-
[Single-donor (apheresis) platelets and pooled whole-blood-derived platelets--significance and assessment of both blood products].Clin Lab. 2014;60(4):S1-39. doi: 10.7754/clin.lab.2014.140210. Clin Lab. 2014. PMID: 24779310 Review. German.
-
The collection of platelets by apheresis procedures.Transfus Med Rev. 1994 Apr;8(2):132-45. doi: 10.1016/s0887-7963(94)70105-x. Transfus Med Rev. 1994. PMID: 8003856 Review.
Cited by
-
Comparative assessment of single-donor plateletpheresis by Haemonetics® MCS® plus and Trima Accel®.Asian J Transfus Sci. 2020 Jan-Jun;14(1):23-27. doi: 10.4103/ajts.AJTS_138_17. Epub 2020 Jul 24. Asian J Transfus Sci. 2020. PMID: 33162701 Free PMC article.
-
A Study on Influence of Donor Hematocrit on the Procedural Parameters of Concentrated Single Donor Platelets Collected by Two Apheresis Devices.Indian J Hematol Blood Transfus. 2020 Jan;36(1):135-140. doi: 10.1007/s12288-019-01163-0. Epub 2019 Jul 27. Indian J Hematol Blood Transfus. 2020. PMID: 32158096 Free PMC article.
References
-
- Schrezenmeier H, Seifried E. Buffy-coat-derived pooled platelet concentrates and aphaeresis platelet concentrates: which product type should be preferred? Vox Sang. 2010;99:1–15. - PubMed
-
- Wiltbank TB, Giordano GF. The safety profile of automated collections: an analysis of more than 1 million collections. Transfusion. 2007;47:1002–5. - PubMed
-
- Despotis GJ, Goodnough LT, Dynis M, et al. Adverse events in platelet apheresis donors: a multivariate analysis in a hospital-based program. Vox Sang. 1999;77:24–32. - PubMed
-
- Burgstaler EA, Pineda AA, Wollan P. Plateletapheresis: comparison of processing times, platelet yields, and white blood cell content with several commonly used systems. J Clin Apher. 1997;12:170–8. - PubMed
-
- Bonomo P, Alfano G, Gandini G, et al. Standard of Transfusion Medicine. second edition. Edizioni SIMTI; Jun, 2010.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources