The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients: a MADIT-CRT substudy (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)
- PMID: 24333490
- DOI: 10.1016/j.jacc.2013.10.074
The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients: a MADIT-CRT substudy (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)
Abstract
Objectives: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD) treatment in mildly symptomatic HF patients with left bundle branch block (LBBB).
Background: Limited data exist regarding the benefit of CRT-D in patients with IAT.
Methods: The benefit of CRT-D in reducing the risk of HF/death was evaluated using multivariate Cox models incorporating the presence of, respectively, a history of IAT at baseline and time-dependent development of in-trial IAT during follow-up in 1,264 patients with LBBB enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.
Results: The overall beneficial effect of CRT-D versus ICD on the risk of HF/death was not significantly different between LBBB patients with or without history of IAT (HR: 0.50, p = 0.028, and HR: 0.46, p < 0.001, respectively; p for interaction = 0.79). Among patients who had in-trial IAT, CRT-D was associated with a significant 57% reduction in the risk of HF/death compared with ICD-only therapy (HR: 0.43, p = 0.047), similar to the effect of the device among patients who did not have IAT (HR: 0.47, p < 0.001; p for interaction = 0.85). The percentage of patients with biventricular pacing ≥92% was similar in both groups (p = 0.43). Consistent results were shown for the benefit of CRT-D among patients who had in-trial atrial fibrillation/flutter (HR: 0.30, p = 0.027; p for interaction = 0.41).
Conclusions: In the MADIT-CRT study, the clinical benefit of CRT-D in LBBB patients was not attenuated by prior history of IAT or by the development of in-trial atrial tachyarrhythmias. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy; NCT00180271).
Keywords: atrial arrhythmia; cardiac resynchronization therapy; death; efficacy; heart failure; implantable cardioverter-defibrillator; left atrial volume; left bundle branch block; reverse remodeling.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Cardiac resynchronization therapy in patients with intermittent atrial arrhythmias: will cardiac resynchronization therapy be good for all?J Am Coll Cardiol. 2014 Apr 1;63(12):1198-1199. doi: 10.1016/j.jacc.2013.11.020. Epub 2013 Dec 11. J Am Coll Cardiol. 2014. PMID: 24333494 No abstract available.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous