Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Jan 7;55(1):117-24.
doi: 10.1167/iovs.13-13290.

Corneal biomechanical properties and glaucoma-related quantitative traits in the EPIC-Norfolk Eye Study

Affiliations
Comparative Study

Corneal biomechanical properties and glaucoma-related quantitative traits in the EPIC-Norfolk Eye Study

Anthony P Khawaja et al. Invest Ophthalmol Vis Sci. .

Abstract

Purpose: We examined the association of corneal hysteresis (CH) with Heidelberg retina tomograph (HRT)- and Glaucoma Detection with Variable Corneal Compensation scanning laser polarimeter (GDxVCC)-derived measures in a British population.

Methods: The EPIC-Norfolk Eye Study is nested within a multicenter cohort study--the European Prospective Investigation of Cancer. Ocular response analyzer (ORA), HRT3, and GDxVCC measurements were taken at the research clinic. Three ORA measurements were taken per eye, and the single best value used. Participants meeting predefined criteria were referred for a second examination, including Goldmann applanation tonometry (GAT) and central corneal thickness (CCT) measurement. Generalized estimating equation models were used to examine the associations of CH with HRT and GDxVCC parameters, adjusted for disc area. The GDxVCC analyses were adjusted further for typical scan score to handle atypical retardation.

Results: There were complete research clinic data from 5134 participants. Corneal hysteresis was associated positively with HRT rim area (P < 0.001), and GDxVCC retinal nerve fiber layer (RNFL) average thickness (P = 0.006) and modulation (P = 0.003), and associated negatively with HRT linear cup-to-disc ratio (LCDR, P < 0.001), after adjustment for Goldmann-correlated IOP and other possible confounders. In the 602 participants undergoing the second examination, CH was associated negatively with LCDR (P = 0.008) after adjustment for GAT, CCT, and other possible confounders.

Conclusions: Lower CH was associated with HRT and GDxVCC parameters in a direction that is seen in glaucoma and with ageing. Further research is required to establish if this is a causal relationship, or due to residual confounding by age, IOP, or CCT.

Keywords: biomechanics; cornea; epidemiology; glaucoma; optic disk; scanning laser polarimetry.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Gordon MO, Beiser JA, Brandt JD, et al. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol. 2002; 120: 714–720, discussion 829–30 - PubMed
    1. Jiang X, Varma R, Wu S, et al. Baseline risk factors that predict the development of open-angle glaucoma in a population: the Los Angeles Latino Eye Study. Ophthalmology. 2012; 119: 1–9 - PMC - PubMed
    1. Leske MC, Wu SY, Hennis A, Honkanen R, Nemesure B. Risk factors for incident open-angle glaucoma: the Barbados Eye Studies. Ophthalmology. 2008; 115: 85–93 - PubMed
    1. Leske MC, Heijl A, Hyman L, Bengtsson B, Dong L, Yang Z. Predictors of long-term progression in the early manifest glaucoma trial. Ophthalmology. 2007; 114: 1965–1972 - PubMed
    1. Herndon LW, Weizer JS, Stinnett SS. Central corneal thickness as a risk factor for advanced glaucoma damage. Arch Ophthalmol. 2004; 122: 17–21 - PubMed

Publication types