A comparison land-water environment of maximal voluntary isometric contraction during manual muscle testing through surface electromyography
- PMID: 24342017
- PMCID: PMC3878641
- DOI: 10.1186/2052-1847-5-28
A comparison land-water environment of maximal voluntary isometric contraction during manual muscle testing through surface electromyography
Abstract
Background: The aim of this study was to compare through surface electromyographic (sEMG) recordings of the maximum voluntary contraction (MVC) on dry land and in water by manual muscle test (MMT).
Method: Sixteen healthy right-handed subjects (8 males and 8 females) participated in measurement of muscle activation of the right shoulder. The selected muscles were the cervical erector spinae, trapezius, pectoralis, anterior deltoid, middle deltoid, infraspinatus and latissimus dorsi. The MVC test conditions were random with respect to the order on the land/in water.
Results: For each muscle, the MVC test was performed and measured through sEMG to determine differences in muscle activation in both conditions. For all muscles except the latissimus dorsi, no significant differences were observed between land and water MVC scores (p = 0.063-0.679) and precision (%Diff = 7-10%) were observed between MVC conditions in the muscles trapezius, anterior deltoid and middle deltoid.
Conclusions: If the procedure for data collection is optimal, under MMT conditions it appears that comparable MVC sEMG values were achieved on land and in water and the integrity of the EMG recordings were maintained during wáter immersion.
Figures
Similar articles
-
Comparison and reproducibility of sEMG during manual muscle testing on land and in water.J Electromyogr Kinesiol. 2011 Feb;21(1):95-101. doi: 10.1016/j.jelekin.2010.05.004. Epub 2010 Jun 8. J Electromyogr Kinesiol. 2011. PMID: 20965128
-
The influence of posture variation on electromyographic signals in females obtained during maximum voluntary isometric contractions: A shoulder example.J Electromyogr Kinesiol. 2022 Feb;62:102319. doi: 10.1016/j.jelekin.2019.05.020. Epub 2019 May 31. J Electromyogr Kinesiol. 2022. PMID: 31171405
-
Mechanical force spinal manipulation increases trunk muscle strength assessed by electromyography: a comparative clinical trial.J Manipulative Physiol Ther. 2000 Nov-Dec;23(9):585-95. doi: 10.1067/mmt.2000.110947. J Manipulative Physiol Ther. 2000. PMID: 11145798 Clinical Trial.
-
Rhomboid muscle electromyography activity during 3 different manual muscle tests.Arch Phys Med Rehabil. 2004 Jun;85(6):987-92. doi: 10.1016/s0003-9993(03)00618-x. Arch Phys Med Rehabil. 2004. PMID: 15179655
-
Optimal normalization tests for shoulder muscle activation: an electromyographic study.J Orthop Res. 1996 Jul;14(4):647-53. doi: 10.1002/jor.1100140421. J Orthop Res. 1996. PMID: 8764876
Cited by
-
A novel method for noninvasive bioelectric measurement utilizing conductivity of seawater.Sci Rep. 2021 Mar 29;11(1):7073. doi: 10.1038/s41598-021-86295-y. Sci Rep. 2021. PMID: 33782448 Free PMC article.
-
Alterations in the Neuromuscular Control Mechanism of the Legs During a Post-Fatigue Landing Make the Lower Limbs More Susceptible to Injury.Bioengineering (Basel). 2025 Feb 24;12(3):233. doi: 10.3390/bioengineering12030233. Bioengineering (Basel). 2025. PMID: 40150697 Free PMC article.
References
-
- Abidin MR, Thacker JG, Becker DG. et al.Hydrofitness devices for strengthening upper extremity muscles. Burn Care Rehabil. 1988;5:199–202. - PubMed
-
- Ikai M, Ishii K, Miyashita M. An electromyographic study of swimming. Jap Res J Phys Educ. 1964;5:55–87.