. 2013 Dec 12;8(12):e76091.
doi: 10.1371/journal.pone.0076091. eCollection 2013.

Baseline levels and temporal stability of 27 multiplexed serum cytokine concentrations in healthy subjects

Affiliations

Baseline levels and temporal stability of 27 multiplexed serum cytokine concentrations in healthy subjects

Angelique Biancotto et al. PLoS One. .

Erratum in

Abstract

Background: Cytokines are humoral molecules that elicit regulatory function in immunologic pathways. The level and type of cytokine production has become critical in distinguishing physiologic from pathologic immune conditions. Cytokine profiling has become an important biomarker discovery tool in monitoring of the immune system. However, the variations in cytokine levels in individual subjects over time in healthy individuals have not been extensively studied. In this study, we use multiplex bead arrays to evaluate 27 analytes in paired serum samples taken seven days apart from 144 healthy individuals in order to assess variations over a short time period.

Methods: Fluorescent bead-based immunoassay (Luminex) was used to measure 27 analytes in serum samples. Measurements were performed on matched samples from 144 healthy donors. To assess inter-plate variability, one arbitrarily selected serum sample was analyzed on each of the first ten plates as bridge sample.

Results: Using the bridge sample, we showed minimal inter-plate variations in the measurement of most analytes. In measurement of cytokines from the 144 patients at two time points, we found that three cytokines (IL-2, IL-15 and GM-CSF) were undetectable and five analytes (RANTES, MCP-1, VEGF, MIP-1β and PDGF-BB) showed significant difference in concentrations at Day 0 compared to Day 7.

Conclusions: The current study demonstrated higher variations in cytokine levels among individuals than were observed for samples obtained one week apart from identical donors. These data suggest that a serum sample from each subject for use as a baseline measurement is a better control for clinical trials rather than sera from a paired cohort.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. Cytokine concentrations in bridge sample.
Results show mean concentrations of analytes for the bridge sample assayed in 10 plates with the bars representing the standard errors of the mean.
Figure 2
Figure 2. Mean concentrations for cytokines in serum samples at Day 0 and Day 7.
Serum cytokine concentrations were measured on matched samples at Day 0 and Day 7. Paired T-tests were performed to measure the significance of the difference of the mean between Day 0 and Day 7. Cytokines for which %CV is higher than 20% are shown with “*”.
Figure 3
Figure 3. Concentrations for three cytokines in serum specimens measured at Day 0 and Day 7 for all 144 healthy volunteers.
Serum cytokine concentrations were measured on samples at day 0 and day 7. Each data point corresponds to a matched measurement at Day 0 (black circle) and Day 7 (black square). These plots demonstrate 3 of the 27 analytes and display RANTES (A), IL-7 (B), IL-9 (C) concentrations.
Figure 4
Figure 4. Correlation between cytokine concentration and age.
Correlations of serum cytokine concentrations versus age were measured on samples at Day 0 and Day 7.

References

    1. Gu Y, Zeleniuch-Jacquotte A, Linkov F, Koenig KL, Liu M et al. (2009) Reproducibility of serum cytokines and growth factors. Cytokine 45: 44-49. doi:10.1016/j.cyto.2008.10.014. PubMed: 19058974. - DOI - PMC - PubMed
    1. Bastarache JA, Koyama T, Wickersham NE, Mitchell DB, Mernaugh RL et al. (2011) Accuracy and reproducibility of a multiplex immunoassay platform: a validation study. J Immunol Methods 367: 33-39. doi:10.1016/j.jim.2011.01.005. PubMed: 21277854. - DOI - PMC - PubMed
    1. de Jager W, Rijkers GT (2006) Solid-phase and bead-based cytokine immunoassay: a comparison. Methods 38: 294-303. doi:10.1016/j.ymeth.2005.11.008. PubMed: 16481197. - DOI - PubMed
    1. Wong HL, Pfeiffer RM, Fears TR, Vermeulen R, Ji S et al. (2008) Reproducibility and correlations of multiplex cytokine levels in asymptomatic persons. Cancer Epidemiol Biomarkers Prev 17: 3450-3456. doi:10.1158/1055-9965.EPI-08-0311. PubMed: 19064561. - DOI - PubMed
    1. Elshal MF, McCoy JP (2006) Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA. Methods 38: 317-323. doi:10.1016/j.ymeth.2005.11.010. PubMed: 16481199. - DOI - PMC - PubMed

Publication types