Assessment of myocardial adrenergic innervation with a solid-state dedicated cardiac cadmium-zinc-telluride camera: first clinical experience
- PMID: 24351314
- DOI: 10.1093/ehjci/jet258
Assessment of myocardial adrenergic innervation with a solid-state dedicated cardiac cadmium-zinc-telluride camera: first clinical experience
Abstract
Aims: To investigate the relationships between regional adrenergic innervation heterogeneity, myocardial perfusion, and contractile function obtained by means of a low-dose imaging protocol with a cadmium-zinc-telluride (CZT) dedicated camera.
Methods: Twenty-eight patients with or without ischaemic heart disease underwent (123)I-metaiodobenzylguanidine (MIBG) planar scintigraphic and CZT early and delayed evaluations followed by (99m)Tc-tetrofosmin rest gated CZT with a single-day protocol. The heart-to-mediastinum ratio and the washout rate were computed from planar (123)I-MIBG images. The summed (123)I-MIBG defect scores (SS-MIBG) were semi-quantitatively assessed from CZT images. The summed rest score (SRS), summed motion score (SMS), and summed thickening score (STS) were quantitated from (99m)Tc-tetrofosmin images.
Results: Sixteen patients showed a depressed left ventricular systolic function [ejection fraction (EF)<50%]. They presented higher SRS (P = 0.007), SMS (P < 0.001), STS (P < 0.001), and early SS-MIBG (P = 0.007) values than those with normal contractile function. Interestingly, higher early SS-MIBG values, index of regional sympathetic innervation heterogeneity, clustered with more elevated SRS (P = 0.023), and more impaired measures of regional and global left ventricle systolic function, i.e. SMS (P = 0.046), STS (P = 0.014), and EF (P = 0.027). At multivariate analysis, a higher SRS (P = 0.039) remained the only independent predictor of more elevated early SS-MIBG values. In the 20 of 28 ischaemic patients, the correlations between early SS-MIBG and SMS (P = 0.017) and also STS (P = 0.036) were further confirmed. The effective dose of the investigation was 4.2 ± 0.72 mSv.
Conclusions: An altered early SS-MIBG, assessed with a low-dose imaging protocol and a CZT cardiac camera, identifies patients with more impaired myocardial perfusion and contractile function.
Keywords: 123I-MIBG; CZT camera; Cardiac innervation; Heart-to-mediastinum ratio.
Similar articles
-
Association between left ventricular regional sympathetic denervation and mechanical dyssynchrony in phase analysis: a cardiac CZT study.Eur J Nucl Med Mol Imaging. 2014 May;41(5):946-55. doi: 10.1007/s00259-013-2640-3. Epub 2013 Dec 6. Eur J Nucl Med Mol Imaging. 2014. PMID: 24310439
-
Dynamic 3D analysis of myocardial sympathetic innervation: an experimental study using 123I-MIBG and a CZT camera.J Nucl Med. 2015 Mar;56(3):464-9. doi: 10.2967/jnumed.114.143669. Epub 2015 Jan 29. J Nucl Med. 2015. PMID: 25635134
-
Determination of the Heart-to-Mediastinum Ratio of 123I-MIBG Uptake Using Dual-Isotope (123I-MIBG/99mTc-Tetrofosmin) Multipinhole Cadmium-Zinc-Telluride SPECT in Patients with Heart Failure.J Nucl Med. 2018 Feb;59(2):251-258. doi: 10.2967/jnumed.117.194373. Epub 2017 Jun 23. J Nucl Med. 2018. PMID: 28646015
-
Cardiac Imaging With 123I-meta-iodobenzylguanidine and Analogous PET Tracers: Current Status and Future Perspectives.Semin Nucl Med. 2020 Jul;50(4):331-348. doi: 10.1053/j.semnuclmed.2020.03.001. Epub 2020 Mar 27. Semin Nucl Med. 2020. PMID: 32540030 Review.
-
Cardiac autonomic imaging with SPECT tracers.J Nucl Cardiol. 2013 Feb;20(1):128-43; quiz 146. doi: 10.1007/s12350-012-9655-1. J Nucl Cardiol. 2013. PMID: 23188628 Review.
Cited by
-
Interactions between myocardial sympathetic denervation and left ventricular mechanical dyssynchrony: A CZT analysis.J Nucl Cardiol. 2019 Apr;26(2):509-518. doi: 10.1007/s12350-017-1036-3. Epub 2017 Aug 14. J Nucl Cardiol. 2019. PMID: 28808889
-
Cardiac 123I-mIBG Imaging in Heart Failure.Pharmaceuticals (Basel). 2022 May 25;15(6):656. doi: 10.3390/ph15060656. Pharmaceuticals (Basel). 2022. PMID: 35745574 Free PMC article. Review.
-
Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).Eur J Nucl Med Mol Imaging. 2016 Dec;43(13):2423-2432. doi: 10.1007/s00259-016-3467-5. Epub 2016 Aug 19. Eur J Nucl Med Mol Imaging. 2016. PMID: 27542010 Review.
-
Left ventricular function assessment using 123I/99mTc dual-isotope acquisition with two semi-conductor cadmium-zinc-telluride (CZT) cameras: a gated cardiac phantom study.EJNMMI Phys. 2016 Dec;3(1):27. doi: 10.1186/s40658-016-0163-2. Epub 2016 Nov 11. EJNMMI Phys. 2016. PMID: 27837548 Free PMC article.
-
First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study.J Nucl Cardiol. 2018 Oct;25(5):1692-1704. doi: 10.1007/s12350-017-0841-z. Epub 2017 Mar 8. J Nucl Cardiol. 2018. PMID: 28275896