Observational Study
. 2014 Jun;16(6):826-33.
doi: 10.1093/europace/eut366. Epub 2013 Dec 18.

Real-time assessment of pulmonary vein disconnection during cryoablation of atrial fibrillation: can it be 'achieved' in almost all cases?

Affiliations
Observational Study

Real-time assessment of pulmonary vein disconnection during cryoablation of atrial fibrillation: can it be 'achieved' in almost all cases?

Serge Boveda et al. Europace. 2014 Jun.

Abstract

Aim: Real-time assessment of pulmonary vein (PV) disconnection is possible using an inner circular mapping catheter during cryoablation of atrial fibrillation (AF). However, it has been recently demonstrated that such continuous monitoring may only be possible in <50% of PVs. We hypothesized that a stepwise mapping approach, including pacing manoeuvres, could optimize monitoring of real-time PV disconnection during ablation.

Methods and results: Single-centre, prospective observational study (NCT01843465) including 34 consecutive eligible patients (128 PVs) undergoing a first procedure of cryoballoon ablation of AF using the Artic Front Advance(®) 28 mm catheter and a 20 mm diameter Achieve(®) catheter (AC) in all cases. Monitoring of real-time entrance block was possible, when AC was maintained in the standard position (distal to the tip of the Artic Front Advance(®) catheter) in 47 (36.7%) PVs. In an additional 63 cases (49.2%), such monitoring was possible after moving AC to a more proximal position and using different torqueing movements. Finally, using supplemental systematic pacing manoeuvres to test exit block, real-time assessment of PV disconnection was possible in 15 (11.7%) more PVs. Overall, real-time assessment of PV disconnection was possible in 97.7% of cases, after a mean duration of 48.6 ± 33.0 s.

Conclusion: Our results suggest that optimal use of the AC, with a systematic stepwise mapping approach, may dramatically improve the real-time monitoring of PV disconnection during AF cryoablation.

Keywords: Achieve catheter; Atrial fibrillation; Cryoablation; Entrance block; Exit block.