Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Jun;79(2):61-6.
doi: 10.4081/monaldi.2013.93.

The correlation between endothelin-1 levels and spirometry in dialysis patients compared to healthy subjects

Affiliations
Free article
Comparative Study

The correlation between endothelin-1 levels and spirometry in dialysis patients compared to healthy subjects

P Kovacević et al. Monaldi Arch Chest Dis. 2013 Jun.
Free article

Abstract

Background and aim: Several studies demonstrated a six-fold increase in plasma concentration of endothelin-1 (ET-1) in diaysis patients (hemodialysis and peritoneal dialysis) compared to healthy control subjects. However, the effects of ET-1 on respiratory function in these patients are less known. The aim of this study was to determine the potential differences in spirometric values in relation to ET-1 levels.

Methods: The study included 28 patients (15 male, 13 female, mean age 55.9 +/- 16. 2 years) with end stage renal diseases (ESRD) receiving regular hemodialysis (HD), 23 patients (10 males, 13 females, mean age 55.8 +/- 15.8 years) with ESRD treated with continuous ambulatory peritoneal dialysis (CAPD) without any cardiovascular or respiratory diseases, and 30 healthy volunteers (14 male, 16 female, mean age 51.8 +/- 15.6 years) in control group. In each of the three groups the participants were divided into two additional sub-groups according to the serum levels of ET-1. The spirometry values were recorded before the onset of hemodialysis and prior to emptying the peritoneal cavity in CAPD patients. The results were analyzed using standard statistical methods (Student's t-test).

Results: Patients who were treated with HD or CAPD were found to have significant difference in values of most pulmonary function parameters between subjects with ET-1 levels lower than 6.6 pg/ml and subjects with ET-1 levels higher than 6.6 pg/ml. In the control group there was no difference in pulmonary function parameters in correlation with ET-1 levels. ET-1 values in patients of both dialysis groups were significantly higher compared to healthy subjects.

Conclusions: Higher levels of ET-1 in dialysis patients over healthy subjects is associated with lower parameters of lung function tests. A possible pathophysiological mechanism for deterioration of pulmonary function might be explained by progression of inflammation, pulmonary oedema also known as "uraemic lung" or/and the progression of pulmonary hypertension.

PubMed Disclaimer

Publication types

LinkOut - more resources