Fungal air quality in hospital rooms: a case study in Tehran, Iran
- PMID: 24355065
- PMCID: PMC3891997
- DOI: 10.1186/2052-336X-11-30
Fungal air quality in hospital rooms: a case study in Tehran, Iran
Abstract
Fungi are usually presented in indoor environments and cause of many diseases. The aim of this descriptive study was to investigate the level of fungal contamination in hospital rooms. Sampling was conducted with an Andersen one-stage viable impactor (Quick Take-30) and counting plates containing a fungus-selective medium. A total of 120 air samples from ten hospital environments were performed. Airborne fungi concentrations were determined 72-120 hours after sampling. Total mean concentration of detected fungi in the hospital rooms was 55 ± 56 (mean ± SD) cfu/m3. The findings of the fungal concentration in the various hospital rooms revealed different levels of contamination: the lowest mean counts (37 ± 17 cfu/m3) were observed in NS 1 (Nursing Stations 1), and the highest (97 ± 217 cfu/m3) were reported in Orthopedics Operating Room (OOR). The most common fungal genus isolated were Penicillium (70%), Aspergillus (14%), Cladosporium (12%), Alternaria (2%) and others (2%). The obtained results showed that fungal concentrations in the present study were nearly high and these conditions should be considered as a risk factor for patients and other persons in the hospital.
Figures
Similar articles
-
Fungal contamination in hospital environments.Infect Control Hosp Epidemiol. 2006 Jan;27(1):44-7. doi: 10.1086/499149. Epub 2006 Jan 6. Infect Control Hosp Epidemiol. 2006. PMID: 16418986
-
[Airborne fungal community composition in indoor environments in Beijing].Huan Jing Ke Xue. 2013 May;34(5):2031-7. Huan Jing Ke Xue. 2013. PMID: 23914564 Chinese.
-
Study on the relationship between the concentration and type of fungal bio-aerosols at indoor and outdoor air in the Children's Medical Center, Tehran, Iran.Environ Monit Assess. 2019 Jan 4;191(2):48. doi: 10.1007/s10661-018-7183-4. Environ Monit Assess. 2019. PMID: 30610385
-
Airborne viable, non-viable, and allergenic fungi in a rural agricultural area of India: a 2-year study at five outdoor sampling stations.Sci Total Environ. 2004 Jun 29;326(1-3):123-41. doi: 10.1016/j.scitotenv.2003.12.007. Sci Total Environ. 2004. PMID: 15142771
-
Two years of a fungal aerobiocontamination survey in a Florentine haematology ward.Eur J Epidemiol. 2004;19(7):693-8. doi: 10.1023/b:ejep.0000036778.13006.16. Eur J Epidemiol. 2004. PMID: 15461201
Cited by
-
Indoor environment assessment of special wards of educational hospitals for the detection of fungal contamination sources: A multi-center study (2019-2021).Curr Med Mycol. 2022 Dec;8(4):1-8. doi: 10.32598/CMM.2023.1370. Curr Med Mycol. 2022. PMID: 37736609 Free PMC article.
-
The Health Literacy Status and Its Role in Interventions in Iran: A Systematic and Meta-Analysis.Int J Environ Res Public Health. 2021 Apr 17;18(8):4260. doi: 10.3390/ijerph18084260. Int J Environ Res Public Health. 2021. PMID: 33920508 Free PMC article.
-
Prevalence of fungi and their antifungal and disinfectant resistance in hospital environments: insights into combating nosocomial mycoses.Antimicrob Resist Infect Control. 2025 Apr 23;14(1):37. doi: 10.1186/s13756-025-01558-x. Antimicrob Resist Infect Control. 2025. PMID: 40269983 Free PMC article.
-
Mycological Methods for Routine Air Sampling and Interpretation of Results in Operating Theaters.Diagnostics (Basel). 2024 Jan 29;14(3):288. doi: 10.3390/diagnostics14030288. Diagnostics (Basel). 2024. PMID: 38337804 Free PMC article. Review.
-
Contamination of obsterics and gynecology hospital air by bacterial and fungal aerosols associated with nosocomial infections.J Environ Health Sci Eng. 2021 Feb 27;19(1):663-670. doi: 10.1007/s40201-021-00637-6. eCollection 2021 Jun. J Environ Health Sci Eng. 2021. PMID: 33680477 Free PMC article.
References
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous