Development of the mechanical properties of engineered skin substitutes after grafting to full-thickness wounds
- PMID: 24356985
- PMCID: PMC4023834
- DOI: 10.1115/1.4026290
Development of the mechanical properties of engineered skin substitutes after grafting to full-thickness wounds
Abstract
Engineered skin substitutes (ESSs) have been reported to close full-thickness burn wounds but are subject to loss from mechanical shear due to their deficiencies in tensile strength and elasticity. Hypothetically, if the mechanical properties of ESS matched those of native skin, losses due to shear or fracture could be reduced. To consider modifications of the composition of ESS to improve homology with native skin, biomechanical analyses of the current composition of ESS were performed. ESSs consist of a degradable biopolymer scaffold of type I collagen and chondroitin-sulfate (CGS) that is populated sequentially with cultured human dermal fibroblasts (hF) and epidermal keratinocytes (hK). In the current study, the hydrated biopolymer scaffold (CGS), the scaffold populated with hF dermal skin substitute (DSS), or the complete ESS were evaluated mechanically for linear stiffness (N/mm), ultimate tensile load at failure (N), maximum extension at failure (mm), and energy absorbed up to the point of failure (N-mm). These biomechanical end points were also used to evaluate ESS at six weeks after grafting to full-thickness skin wounds in athymic mice and compared to murine autograft or excised murine skin. The data showed statistically significant differences (p <0.05) between ESS in vitro and after grafting for all four structural properties. Grafted ESS differed statistically from murine autograft with respect to maximum extension at failure, and from intact murine skin with respect to linear stiffness and maximum extension. These results demonstrate rapid changes in mechanical properties of ESS after grafting that are comparable to murine autograft. These values provide instruction for improvement of the biomechanical properties of ESS in vitro that may reduce clinical morbidity from graft loss.
Figures





Similar articles
-
Randomized, Paired-Site Comparison of Autologous Engineered Skin Substitutes and Split-Thickness Skin Graft for Closure of Extensive, Full-Thickness Burns.J Burn Care Res. 2017 Mar/Apr;38(2):61-70. doi: 10.1097/BCR.0000000000000401. J Burn Care Res. 2017. PMID: 27404165 Free PMC article. Clinical Trial.
-
Composition and Performance of Autologous Engineered Skin Substitutes for Repair or Regeneration of Excised, Full-Thickness Burns.J Burn Care Res. 2023 Jan 2;44(Suppl_1):S50-S56. doi: 10.1093/jbcr/irac107. J Burn Care Res. 2023. PMID: 35917370
-
Inflammatory response and biomechanical properties of coaxial scaffolds for engineered skin in vitro and post-grafting.Acta Biomater. 2018 Oct 15;80:247-257. doi: 10.1016/j.actbio.2018.09.014. Epub 2018 Sep 12. Acta Biomater. 2018. PMID: 30218778
-
Tissue-engineered skin. Current status in wound healing.Am J Clin Dermatol. 2001;2(5):305-13. doi: 10.2165/00128071-200102050-00005. Am J Clin Dermatol. 2001. PMID: 11721649 Review.
-
Principles and practices for treatment of cutaneous wounds with cultured skin substitutes.Am J Surg. 2002 Apr;183(4):445-56. doi: 10.1016/s0002-9610(02)00813-9. Am J Surg. 2002. PMID: 11975935 Review.
Cited by
-
Bioprinting: From Tissue and Organ Development to in Vitro Models.Chem Rev. 2020 Oct 14;120(19):10547-10607. doi: 10.1021/acs.chemrev.9b00789. Epub 2020 May 14. Chem Rev. 2020. PMID: 32407108 Free PMC article. Review.
-
A Micro-Scale Non-Linear Finite Element Model to Optimize the Mechanical Behavior of Bioprinted Constructs.3D Print Addit Manuf. 2022 Dec 1;9(6):490-502. doi: 10.1089/3dp.2021.0238. Epub 2022 Dec 13. 3D Print Addit Manuf. 2022. PMID: 36660750 Free PMC article.
-
Accounting for Material Changes in Decellularized Tissue with Underutilized Methodologies.Biomed Res Int. 2021 May 31;2021:6696295. doi: 10.1155/2021/6696295. eCollection 2021. Biomed Res Int. 2021. PMID: 34159202 Free PMC article. Review.
-
Advancements in Regenerative Strategies Through the Continuum of Burn Care.Front Pharmacol. 2018 Jul 9;9:672. doi: 10.3389/fphar.2018.00672. eCollection 2018. Front Pharmacol. 2018. PMID: 30038569 Free PMC article. Review.
-
Antibacterial Properties of Polymeric Membranes Containing Doxycycline for Potential Applications in Foot Ulcer Treatment.Int J Mol Sci. 2025 Apr 1;26(7):3274. doi: 10.3390/ijms26073274. Int J Mol Sci. 2025. PMID: 40244106 Free PMC article.
References
-
- Boyce, S. T. , 2004, “Fabrication, Quality Assurance, and Assessment of Cultured Skin Substitutes for Treatment of Skin Wounds,” Biochem. Eng. J., 20(2), pp. 107–112, 200410.1016/j.bej.2003.09.017 - DOI
-
- American Burn Association, 2013. National Burn Repository, American Burn Association, Chicago, IL.
-
- Zeng, Q. , Macri, L. K. , Prasad, A. , Clark, R. A. F. , Zeugolis, D. I. , Hanley, C. , Garcia, Y. , and Pandit, A. , 2011, “Skin Tissue Engineering”, Comprehensive Biomaterials, Ducheyne P., Healy K., Hutmacher D. E., Grainger D. W., and Kirkpatrick C. J., eds., Elsevier, Philadelphia, PA, pp. 467–499.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous