Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Mar;78(3):232-6.
doi: 10.1016/j.diagmicrobio.2013.11.016. Epub 2013 Nov 27.

Influenza and respiratory syncytial virus detection in clinical specimens without nucleic acid extraction using FOCUS direct disc assay is substantially equivalent to the traditional methods and the FOCUS nucleic acid extraction-dependent RT-PCR assay

Affiliations
Comparative Study

Influenza and respiratory syncytial virus detection in clinical specimens without nucleic acid extraction using FOCUS direct disc assay is substantially equivalent to the traditional methods and the FOCUS nucleic acid extraction-dependent RT-PCR assay

Suresh B Selvaraju et al. Diagn Microbiol Infect Dis. 2014 Mar.

Abstract

In this study, we evaluated FOCUS diagnostic's Flu A/B & RSV direct kit (Direct Disc assay), designed to detect influenza (FLU) and respiratory syncytial viruses (RSV) directly in clinical specimens without nucleic acid extraction. This novel 'sample-to-answer', nucleic acid extraction-independent assay uses a unique disc to process, amplify, and detect viral targets in up to 8 specimens at a time. The performance of this assay for detecting FLU and RSV viruses was compared to the traditional methods (culture and/or direct florescent antibody testing) using 945 nasopharyngeal swab specimens. In addition, a total of 150 consecutive clinical specimens positive for FLU (FLU A=50, FLU B=50) or RSV (n=50) were tested in parallel using the novel Direct Disc assay and FOCUS diagnostic's nucleic acid extraction-dependent assay to assess their relative performance. Compared to the traditional methods, the overall (prospective+retrospective) positive/negative percent agreement was determined to be 96.6%/98.1% for FLU A, 98.4%/99.9% for FLU B, and 99.3%/98.8% for RSV. Compared to the nucleic acid extraction-dependent assay, the positive percent agreement was 90% (n=45/50) for FLU A, 92% (n=46/50) for FLU B, and 98% (n=49/50) for RSV. Overall, the Direct Disc assay showed good agreement with both traditional methods and nucleic acid extraction-dependent assay. Although we encountered some failures compared to the nucleic acid extraction-dependent assay, these limitations must be balanced against the substantial advantages of the extraction-free nature of this assay and rapid turnaround time.

Keywords: Direct Disc assay; FOCUS nucleic acid extraction–dependent assay; Flu and RSV detection; Nasopharyngeal swab specimens; Simplexa.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources