Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1987 May;36(5):578-84.
doi: 10.2337/diab.36.5.578.

Progress toward standardization of cytoplasmic islet cell-antibody assay

Comparative Study

Progress toward standardization of cytoplasmic islet cell-antibody assay

H Gleichmann et al. Diabetes. 1987 May.

Abstract

Cytoplasmic islet cell autoantibodies (ICAs) of 13 coded sera were determined by 26 laboratories. ICAs were determined by 24 laboratories according to a standard protocol based on the conventional indirect-immunofluorescence technique on cryostat sections of human pancreas. In addition, these 24 laboratories had performed any of 8 modifications of the assay. Test samples were titrated to end point, and the results obtained with the different methods were compared with those obtained by the standard protocol. The remaining 2 laboratories used either exclusively pancreatic sections of monkey instead of human as substrate (lab 23) or applied immunohistochemical staining (lab 22). By following the standard protocol, interlaboratory concordance was greater than 90% for the presence or absence of islet cell antibodies in 7 of the 13 samples circulated. However, a wide variability of titers was recorded, ranging from negative to 128. Of the modifications, prolonged incubation in the presence of aprotinin was performed by 10 laboratories and was found to improve the sensitivity in 57 of 70 (81%) determinations with samples that had been ICA positive by the standard protocol. Improved sensitivity was also noted by 2 laboratories with sections of monkey pancreas. Acetone-fixed sections, used by 6 laboratories, or a two-color immunofluorescence method, applied by 3 laboratories, did not change the titers in 27 of 35 (77%) and 14 of 25 (56%) determinations with samples that had been ICA positive by the standard protocol. In contrast, heat inactivation of the samples before testing, performed by 5 laboratories, resulted in a decrease in titers in 25 of 39 (64%) determinations.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources