Estimation of measurement uncertainty of polychlorinated biphenyls, polycyclic aromatic hydrocarbons and organochlorine pesticides in the atmosphere using gas chromatography-mass spectrometry and gas chromatography-electron capture detector
- PMID: 24369999
- DOI: 10.1016/j.chroma.2013.12.005
Estimation of measurement uncertainty of polychlorinated biphenyls, polycyclic aromatic hydrocarbons and organochlorine pesticides in the atmosphere using gas chromatography-mass spectrometry and gas chromatography-electron capture detector
Abstract
Estimation of uncertainty of measurement is a crucial issue to achieve accurate measurement results. When the target has adverse environmental and health effects, accuracy of the results become more important. POPs are the pollutants that have toxic effects and unfortunately, there is a lack of information about uncertainty of the method for determining POPs in air samples. In this work, uncertainty calculations were carried out for PCBs, OCPs, and PAHs in air samples analyzed by using GC-MS and GC-ECD. The main dominant sources for combined uncertainty were calibration curve, recovery and repeatability. The relative uncertainties were found to be in the range of 23-52% for PCBs, 24-59% for OCPs and 23-90% for PAHs.
Keywords: Air samples; Gas chromatography; Organochlorine pesticides; Polychlorinated biphenyls; Polycyclic aromatic hydrocarbons; Uncertainty.
Copyright © 2013 Elsevier B.V. All rights reserved.
Similar articles
-
Estimation of measurement uncertainty of pesticides, polychlorinated biphenyls and polyaromatic hydrocarbons in sediments by using gas chromatography-mass spectrometry.Anal Chim Acta. 2012 Apr 29;724:20-9. doi: 10.1016/j.aca.2012.02.050. Epub 2012 Mar 8. Anal Chim Acta. 2012. PMID: 22483205
-
Trace-level analysis of polychlorinated biphenyls, organochlorine pesticides and polycyclic aromatic hydrocarbons in human plasma or serum by dispersive liquid-liquid microextraction and gas chromatography-tandem mass spectrometry.Biomed Chromatogr. 2022 Jun;36(6):e5360. doi: 10.1002/bmc.5360. Epub 2022 Mar 31. Biomed Chromatogr. 2022. PMID: 35261063
-
Simultaneous determination of PCBs, OCPs and PAHs in mussel by ultrasound-assisted cloudy extraction and gas chromatography-tandem mass spectrometry.Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2020 Oct;37(10):1730-1743. doi: 10.1080/19440049.2020.1798029. Epub 2020 Aug 18. Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2020. PMID: 32811350
-
Status of POPs accumulation in the Yellow River Delta: From distribution to risk assessment.Mar Pollut Bull. 2016 Jun 15;107(1):370-378. doi: 10.1016/j.marpolbul.2016.03.063. Epub 2016 Apr 14. Mar Pollut Bull. 2016. PMID: 27085594 Review.
-
Developments in the use of chromatographic techniques in marine laboratories for the determination of halogenated contaminants and polycyclic aromatic hydrocarbons.J Chromatogr A. 2003 Jun 6;1000(1-2):223-51. doi: 10.1016/s0021-9673(03)00309-1. J Chromatogr A. 2003. PMID: 12877173 Review.
Cited by
-
Simultaneous analysis of organochlorine pesticides and polychlorinated biphenyls in air samples by using accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) coupled to gas chromatography dual electron capture detection.Environ Sci Pollut Res Int. 2016 Apr;23(8):8053-63. doi: 10.1007/s11356-016-6072-z. Epub 2016 Jan 16. Environ Sci Pollut Res Int. 2016. PMID: 26780048
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical